Ecp Zone Expander (2-44+ Only); Zone Expander Outputs - Honeywell Galaxy 2 Series Installation Manual

Hide thumbs Also See for Galaxy 2 Series:
Table of Contents

Advertisement

ECP Zone Expander
ECP Zone Expander (2–44+ Only)
This is an expander for use on panels that use the ECP communication Bus. Up to three zone expanders can
be fitted to the Galaxy 2–44+ panel. Each expander gives 8 extra hardwired zones and four programmable
outputs. An alternative expander gives four extra hardwired zones and no outputs.
(not fitted in 4-zone version)
12V Pull-up
Jumpers
Tamper
Switch
Tamper
By-pass
Switch

Zone Expander Outputs

The four outputs are switched 0V (0V active). Without the jumper they will float in the 'OFF' state (see
Figure 23). They can apply a +12V signal, if required, by fitting the appropriate pull-up jumper supplied (see
Figure 24). (This is typically required for activating comms devices). All devices wired to the outputs must
have their negative terminals wired to the switched output, and their positive terminals wired to the + 12V
output.
+12 V
3k3Ω
Jumper
not
required
Output
terminal
0 V
Figure 23. Output without jumper
Outputs
Data Input/
Data Output
1
2
3
4
B
DI
SW 1
1
2
Figure 22. Zone Expander Outputs
+12 V
+
Siren
-
Galaxy 2 Series Installation Manual
12V
Output
12V
Input
- +12V - +12V
A
DO
I/P
O/P
Engineer
Socket
Data LED
5
6
8
3
4
7
Zone Terminals
(zones 5-8 not fitted in 4-zone version)
+12 V
3k3Ω
Jumper
fitted
0 V
Figure 24. Output with jumper
32
Address
LK8
Select
LK9
ZD1-0130
Input to
Output
terminal
dialler/Redcare