51 - Parameters (cont'd)
07 = Intruder Resets
This parameter dictates what type of reset is required for a signalled intruder alarm. There are two settings:
0. User
This setting allows any user programmed with the following user types: user, manager, master, to reset a full
intruder alarm.
1. Remote (default)
This setting requires an engineer or remote reset for a signalled intruder alarm. If this option is selected on a
system where confirmed alarms are used, then the reset level required for an unconfirmed alarm can be re-
duced to user, if required, in parameter 51.55.5. This is the default setting for DD243 compliant systems.
08 = Exit Terminate
If Exit Terminate is enabled for Full, Part or Night Set, exit times for the selected mode will be set to infinity.
For Full Set this overrides the value programmed in the Exit Time option (Option 04=Exit Time).
Setting of the system is terminated when an Exit Terminate zone is opened during the exit time. There is a five
second delay between the closing of the Exit Terminate zone and the setting of the system to allow entry route
detectors to settle.
NOTE: The operation (opening and closing) of Exit Terminate zones has no effect on the system except
during the setting procedure.
The settings for Exit Terminate are:
0. No
1. Full set only
2. Full and part set only
3. All set modes
09 = Zone Lockout
This parameter determines the number of times a zone can activate during a set period before it is omitted
from the system. The counter is reset when the panel is unset.
0 - 9 Events.
0 = No lockout
10 = Horn Volume
This parameter sets the volume of the entry/exit horn via the loudspeaker. The range is 00-31. Setting the
volume to 00 makes it silent. Alarm tones are not affected by the volume control.
11 = Audible Power Fault
This parameter has two settings:
0. No
1. Yes (AC fail, Batt low).
When set to 1 (Yes) an alert indication is given immediately at the keypad (see parameter 23). Visual indica-
tion is always given on keypads. These indications are signalled to the ARC after the time programmed in
menu 56.7.04=Comms.Parameters.Power Delay. No audible indication is given when the system is set.
NOTE: When set to 0 (No) no audible indication is given. It is only visible on keypad.