56 - Comms (cont'd)
10 = STU Line Fail
This parameter determines the line fail monitoring for the STU and has two options:
0 = No (default)
1 = Yes
11 = Remote Date
This parameter allows the panel to be programmed to initiate a remote servicing call automatically on a pre-
determined date and time. It will dial out on the appropriate comms module as dictated in 56.6 HW priority.
There are two sub-options:
1 = Call Date
The date is in the format DD/MM/YY
2 = Call Time
The time is in the format HH:MM
12 = Remote ID
This option allows a 10-digit identification number to be entered to allow the system to be uniquely identified
to remote servicing software.
8 = 2-Way Voice (2–44+ Only)
This menu option has three sub-options:
1 = Listen in
This option allows an operator to listen to the audio on site after the panel sends an alarm signal to the ARC.
1 = Intruder
When set to Yes this option enables listen-in after an intruder or entry timeout transmission.
2 = Confirm
When set to Yes this option enables listen-in after a confirm transmission.
3 = Others
When set to Yes this option enables listen-in after a Fire, PA audible, PA silent or Assistance transmission.
2 = ARC Tel Nos
This option selects which receiver no's can operate with the listen-in function.
1 = Tel No1
2 = Tel No2
3 = Dial in
This option allows a user to dial-in and enter a PIN code to operate the 2-way voice function. See Menu 42.1
(User 99)
1 = Mode
This option, when set to Yes, enables this function.