51 - Parameters (cont'd)
3. RF Jam
This option selects whether or not the system can be set while there is an RF Jam (interference condition)
present.
4. TEL Line Fault
When set to on a line fault can be detected by the panel.
A line fail prevents setting.
19 = Part Bells
This option determines whether the External Bell and Strobe outputs activate during an alarm condition when
the system is Part Set.
0. No
1. Yes
NOTE: Internal sounders always sound.
20 = Night Bells
This option determines whether the External Bell and Strobe outputs activate during an alarm condition when
the system is Night Set.
0. No
1. Yes
This option defaults to 1(Yes).
Note: Internal sounders always sound.
21 = Reset Manager
This parameter must only be used if the Master Manager code is lost or must be replaced. On selecting the
Reset MGR parameter, a warning message is displayed: WARNING!!! ENT=Code Change; press the
ent key to erase current code and reset it to the default of 1234.
22 = Technistore
A user code can cancel an alarm activation but a Technistore reset number must be entered to restore the
system. This parameter has two options:
1. Mode
0 = Off
1 = On (in parallel to other resets)
2. Version 000 (0-255)
The engineer can program the Technistore Version number with a valid range of 000 - 255.
23 = Alerts
This parameter has three settings and dictates how alert indications are presented to the user.
1. Audible and Visible
2. Audible Only
3. Visible Only
Alert indications are given in the unset state only. Audible alerts are given on keypad buzzers and internal
speakers.
Galaxy 2 Series Installation Manual
64