Alarm Notification - DEVA Broadcast DB7000 Maintenance And Operating Instructions

Dsp-based fm radio re-broadcast receiver with tcp/ip connectivity
Hide thumbs Also See for DB7000:
Table of Contents

Advertisement

ALARM NOTIFICATION

The E-mail, SMS, SNMP trap Alarm Notifications contain the following information - device's
Alias, date and time of Alarm triggered, frequency and information about the Alarm activation/
deactivation. The basic signal parameters are also included.
Example for E-mal Notification:
Date: 04 Nov 2012, 07:31:11
DB7000 reports ACTIVE alarm on 99.90MHz
Alarm: RDS > 6.5kHz
Signal parameters:
RF: 51.5dBuV
MPX Total: 89.9kHz
MPX Power: -128.0dBr
Pilot: 7.5kHz
RDS: 11.4kHz
Left: -7.2dB
Right: -8.2dB
Example for SMS Notification:
ACTIVE ALARM
27.09.2013 09:08:34
FREQ:95.7MHz
RF:35.0dBuV *L*
MPX:60.3kHz
Left:-2.8dB
Right:-3.1dB
Pilot:7.92kHz
RDS:4.12kHz
NOTE:
*L* for LOW (below threshold), *H* for HIGH (above threshold)
ATTENTION:
Because of the SMS length limitations, only the most important parameters are
included.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com