Parameter Name
Type
Home Screen
INT
Fan Control
ENUM
Weblog Max Days
ENUM
Factory Defaults
Apply to
ENUM
Execute
ENUM
NOTE 1:
Default values for complex alarm parameters are as follows:
Parameter Name
For all Alarms
Trigger
Release
SMS
Email
SMNP
GPO
RF Alarm
Low threshold
High threshold
MPX Alarm
Low threshold
High threshold
Pilot Alarm
Low threshold
High threshold
RDS Alarm
Range
0 ... 3, step 1
Auto, 25 %, 50%, 75%, 100%
Infinite, 5, 10, 15, 20, 25, 30
None, Channels, Retain Comm, All
Done, Proceed
Type
Range
TIMER
1 ... 600, step 1
TIMER
1 ... 600, step 1
ENUM
ON, OFF
ENUM
ON, OFF
ENUM
ON, OFF
ENUM
1, 2, 3, 4, 5, 6, 7, OFF
INT
20 ... (High threshold)
INT
(Low threshold) ... 100
INT
0 ... (High threshold)
INT
(Low threshold) ... 125
INT
0 ... (High threshold)
INT
(Low threshold) ... 15
Default value [, Unit]
1
Auto, %
Infinite, days
None
Done
Default value [,Unit]
300, sec
300, sec
OFF
OFF
OFF
OFF
25, dBµV
75, dBµV
30, kHz
75, kHz
4, kHz
8, kHz
- 78 -
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com
Description
Select Device's home screen
Fan speed control
Maximum age of WEB system log
Factory defaults settings
Selects parameter group to apply defaults
Revert defaults to selected parameter goup
Description
Alarm active event delay
Alarm idle event delay
SMS notification control
Email notification control
SNMP notification control
GPO pin assignment control
Low alarm trigger level
High alarm trigger level
Low alarm trigger level
High alarm trigger level
Low alarm trigger level
High alarm trigger level