E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com Introduction DEVA Broadcast Ltd. is an international communications and high-technology manufacturing organization, its corporate headquarters and facility located in Burgas, Bulgaria. The company serves the broadcast and corporate markets worldwide – from consumers and small businesses to the largest global organizations.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com Typographic conventions The following table describes important conventions used in the manual. Convention and Style Description Examples Menu > Sub Menu > Click Settings >...
The generated spectrum diagram shows the RF Level vs. the channels. In addition to its wide array of features, the DB7012 receiver is easy to control and setup. The unit can be programmed through the front-panel menu or remotely through your PC, tablet or smart phone via a standard web browser;...
Communication Front panel Ethernet Because of the all-digital, minimalist-discrete-component nature of device circuitry, we have not provided schematic diagrams of the DB7012 in this Manual. Please, note that: NO USER-SERVICEABLE COMPONENTS INSIDE. REFER ALL SERVICING TO QUALIFIED TECHNICAL PERSONNEL. - 10 -...
DEVA Broadcast Ltd. declines all responsibility if any one of the safety rules given herein is not observed. DEVA Broadcast Ltd. declines all responsibility if the end-user resells the product.
E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com Panel Indicators, Switches and Connectors OLED DISPLAY DB7012 has easy to read, high-resolution OLED graphical display that visualizes all measurements of the received signal and DB7012’s settings. LED METERS The full-time LED meters allow quick and easy monitoring of the metering, making the setup, adjustment and programming easy.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com REAR PANEL CAUTION: TO PREVENT ELECTRICAL SHOCK, MAX RF LEVEL 100-240VAC MADE IN BULGARIA 50-63Hz, 25VA DISCONNECT POWER BEFORE SERVICING 90 dB V µ...
For normal operation of DB7012, we recommend following the instructions listed below. • Install the unit in places with good air conditioning. DB7012 is designed to operate within the ambient temperature range of 10 to 50°C. The equipment rack should be ventilated in order for the device to keep its internal temperature below the maximum ambient temperatures;...
Upon receipt, the equipment should be inspected for possible shipping damages. If such are found or suspected, notify the carrier at once and contact DEVA Broadcast Ltd. The original shipping carton box and packing materials should be kept for possible reuse, in case of return for Warranty repair, for example.
Mounting RACK REQUIREMENTS The DB7012 mounts in a standard 19-inch equipment rack and requires only 1¾ inches (1U) of vertical rack space. In order the painted finish around the mounting holes to be protected, the use of plastic washers is recommended.
- 100 - 240 VAC - 1 Amp Fuse CAUTION: Permanent damage will result if improper AC supply voltage is applied to DB7012 device. Your warranty does not cover damages caused by applying improper supply voltage, or use of an improper fuse.
Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com Getting Started In order for the normal operation of the DB7012 to be guaranteed, you will need fulfill the following conditions: 1. Standard Ethernet 10/100M connection; 2. Correctly assigned Network configuration and device settings.
Assigned by DHCP HTTP Port The DB7012 is controlled trough a build in WEB Server and a standard Web browser can be used to monitor its status or to make some adjustments. To operate the device you need to know its IP Address.
After a few seconds the start-up screen will disappear, replaced by the main screen. This is the starting point of the navigation process. DB7012’s OLED display has three function areas: header, soft buttons and main screen working area.
Page 22
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com There are several parameter types available in DB7012. The way of editing depends of the parameter type. Every parameter type has its own editing rules. Numerical parameter Represents numerical value.
Page 23
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com Timer Represents relative time interval. Example: Front panel buttons usage: [UP] / [DOWN] – Increments/decrements value with one step. The unit value will be changed automatically from seconds to minutes and vice-versa;...
Page 24
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com [Insert] – Inserts blank space before the selected character: – before – after [Delete] – Deletes the selected character: – before –...
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com HOME SCREEN The home screen contains all the needed information as regards the signal received. The header is located on the left part of the screen. The header content is determined according to the work area context and may include the functions described below.
Page 26
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com The soft buttons [SB1], [SB2] and [SB3] could be assigned with quick access presets. [SB4] opens a menu containing the full preset list and controls to edit presets. The [UP] and [DOWN] buttons will visualize list with all available services.
NAVIGATION BUTTONS [UP], [DOWN], [LEFT], [RIGHT] and [OK] buttons are used to navigate through the menus, for selecting various functions and parameters of DB7012. The main menu structure has an up- and-down basis, expanded with left-to-right branches. - 27 -...
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com MENU PAGES TUNER This menu allows you to change the DAB Channel and apply changes to the currently selected DAB/DAB+. - 28 -...
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com OUTPUT The settings applied through this menu have influence on the audio level of the analog and digital outputs. SETUP Enter the main Menu page, select Setup icon and press [OK]. The Setup menu is organized into a hierarchical tree menu and all similar parameters are grouped into sections (branches).
If you do not manage to unlock the front panel with the default password, nevertheless whether it has been changed intentionally or not, DB7012 should be returned to its factory defaults in order for the password security to be disabled.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com MONITORING This menu pages allow you configure Logger Services. There is submenu page for each Channel containing Service Settings. For more information of Logger and Services please refer to “Logger”...
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com Alarms set-up – Option 1 The bar graph indicates the signal range of the alarm. The highlighted area represents the permitted signal value range. If current signal value is in this range, no alarm event will be generated.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com STATUS The basic/general information on the device is found here: • Device – Model, Serial number, Firmware version in use, Calibration, Storage capacity; •...
On the Left is the so called “dashboard” of the device - General Tuner and Channel readings, functional buttons. This section of the WEB interface is constant part of each screen, hence allowing immediate tuner interactions. DB7012 “dashboard” content: 1. DAB+ Logo 2. Frequency indicator showing currently tuned frequency;...
Page 35
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com Drop-down Select Service menu options: A list containing all services available in the current Ensemble. - 35 -...
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com MAIN The Main Screen of the WEB Interface shows all the mandatory parameters represented as LED readings and the current DAB station status (DAB Station). You can easily select the preferred audio frequency by using the selection buttons, placed on the left part of the screen.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com LOUDNESS This page shows the average program loudness measurements as defined by ITU BS.1770-4 and EBU R128 recommendations. The following measurements are available: Momentary –...
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com ENSEMBLE Ensemble Information as regards the currently selected ensemble as regards the Channel, Label, Ensemble ID, Workload, number of available Services and Sub-channels, SNR (signal-to-noise) and CNR (carrier-to-noise) indicators in dB can be found in this section.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com SERVICE This page contains information on all the mandatory parameters of the currently selected service. Slideshow is also displayed (if available). - 39 -...
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com BAND SCAN The bandscanning mode could be customized by setting range of the scan. Once you have set range and specified whether all results or the Valid only will be shown, the [Start] button should be pressed in order for the Bandscan process to be initiated.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com STATUS The status tab shows the alarm status of each parameter of the preset frequencies, along with the basic device and network status (IP address, MAC, etc.). If a GSM modem is connected, the status of the modem will also be depicted in the relevant section.
Here are listed all the Device System Events. The local measurements and logs are saved in the internal device memory. All log files can be downloaded via the built-in FTP server. For information on how the connection between the DB7012 and an FTP Client should be configured, please refer to “Download files via FTP”...
Settings bar remains locked. In order for the security of DB7012 to be enhanced, a new username and password could be set from the Security section. By choice, you can change the name of the device (General section).
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com TUNER SETTINGS The Tuner Section gives control over Tuner settings, allowing you to select a DAB channel and service. All available services will be listed below once the list is collected from the multiplex data. - 44 -...
Trough this section of the WEB Interface, services could be chosen and monitored, by applying the needed settings. When the desired adjustments are being made, DB7012 will monitor all of the selected services at regular intervals. All of the collected information is accessible through the built-in FTP Server.
E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com LOGGER SERVICE SETTINGS (SERVICE 1) The DB7012 can monitor up to 24 preset DABServices at regular intervals and send alarm notification via E-mail, SMS, SNMP and GPO. Every Channel consists of a group of settings (explained in details below), which are used when monitoring and alerting. Each preset has its own page where it is being configured.
Page 47
In order for the applied settings to be used press the [Save] button, placed on the bottom right part of the screen. [Export] will export the currently applied alarms settings. [Import] allows you to import the Service settings from other DB7012. - 47 -...
DHCP client to be activated, the function should be enabled. When the DHCP client is activated, all assigned values will be shown in the relevant fields on the Status Screen. If due to any reason, the DHCP procedure cannot be completed, DB7012 will use AutoIP and will generate an IP Address.
Page 49
Once all needed settings are applied, use the [Test] button to generate a test notification, which upon success will be received by the SNMP Manager. Press the [Download] button to download the latest available DB7012 SNMP MIB file. NOTE: The MIB file may vary from one firmware revision to another. Downloading this file from the device, guarantees that you have the proper MIB file.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com OUTPUTS SETTINGS The general purpose outputs settings are applied through this page. Function, type and pulse time for each of the GPOs could be set individually. You can choose between the available functions. Type is used for specifying of the active level.
[All except IP] – all settings, except for the Network settings (IP Address) will be deleted. To restore DB7012 to its Factory Defaults, press [All except IP]. A new window will appear – confirm that you want to restore the factory defaults and wait for the process to be completed. On completion of the process, the settings should have the proper default values.
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com APPENDIX A ALARM TRIGGERS After collecting all the data, the DSP-based core compares the values measured with the predefined by the user threshold levels, for all the parameters monitored. In case that a parameter is beyond limits, the device will initiate the sending of an alarm or warning notification via the selected communication path.
Page 53
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com When an observation event takes place, the Alarm Trigger’s State will refresh, if necessary. Should we consider an instance when the Alarm Trigger is in Idle state, having in mind that an alarm is not triggered immediately when a parameter level passes beyond threshold: If the parameter level becomes stable, within Thresholds, and the Alarm Trigger Time is not elapsed, then the Alarm Trigger remains in Idle state.
Alias, date and time of Alarm triggered, channel number, frequency and information about the Alarm activation/deactivation. The basic signal parameters are also included. Example for E-mal Notification: Date: 04 Nov 2018, 07:31:11 DB7012 reports ACTIVE alarm on 0x1234 - Power FM (CH1) Alarm: S/N Ratio < 16dB Signal parameters: RF: 31dBuV...
The DEVA DAB/DAB+ Monitoring receivers supports a very wide range of GSM Modems. However, we suggest the usage of the following model - Sierra Wireless AirLink. This is the modem that is provided from DEVA Broadcast if the feature has been ordered along with the DEVA Units.
The described Feature is compatible with following DEVA Units: - DB46 – Compact DAB/DAB+ Monitoring Receiver - DB7012 – Professional DSP-based DAB/DAB+ Monitoring Receiver The DEVA Unit can send you a report with the values of the most important parameters at any time.
DEVA Units: - DB46 – Compact DAB/DAB+ Monitoring Receiver - DB7012 – Professional DSP-based DAB/DAB+ Monitoring Receiver 1. Setting up the modem Prior to connecting/using the GSM modem for the first time, kindly read the manufacturer’s user manual.
Page 58
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com Upon powering on, the modem should start working with its factory settings. To see these settings type the command “AT&V”. The modem will respond with the factory default settings: Q:0 V:1 S0:000 S2:043 S3:013 S4:010 S5:008 +CR:0 +CRC:0 +CMEE:0 +CBST:0,0,1 +SPEAKER:1 +ECHO:0 &C:0 &D:2 %C:0...
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com 2. Connecting with DEVA Unit Communication Cable Description: DEVA Unit port GSM modem Note DB 15 female DB 15 male –> com TX –>...
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com APPENDIX C HOW SHOULD I CONFIGURE THE CONNECTION BETWEEN MY DEVA DEVICE AND AN FTP CLIENT? In order for a connection to be established the following setting should be applied: 1.
Page 61
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria Tel: +359 56 820027, Fax: +359 56 836700 E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com 3. Example of FTP Client (FileZilla) Settings In some cases, FileZilla’s “Quick connect” feature is not able to connect with the DEVA unit. That is why we recommend the device to be assigned in the program manually.
B. This Warranty applies only to products sold “as new.” It is extended only to the original end- user and may not be transferred or assigned without prior written approval by DEVA Broadcast Ltd. C. This Warranty does not apply to damage caused by improper mains settings and/or power supply.
Your signature* *Signing this warranty registration form you are stating that all the information provided to DEVA Broadcast Ltd. are truth and correct. DEVA Broadcast Ltd. declines any responsibility for the provided information that could result in an immediate loss of warranty for the above specified product(s).
Need help?
Do you have a question about the DB7012 and is the answer not in the manual?
Questions and answers