ALARM NOTIFICATION

The E-mail, SNMP trap alarm notifications contain the following information - device's
Alias, date and time of alarm triggered, frequency and information about the alarm activation/
deactivation. The basic signal parameters are also included.
Example for E-mal Notification:

Example Stereo Recover

Date: 01 Apr 2015, 16:48:36
DB3011 reports IDLE alarm
Idle: Stereo RECOVERED
Signal parameters:
RF: 21dBuV
Stereo: OK
FM Tuner Left: -11.6dBFs
FM Tuner Right: -11.6dBFs
Link: OK
IP Stream: OK
Stream Left: -11.3dBFs
Stream Right: -10.4dBFs

Example Stereo Loss

Date: 01 Apr 2015, 17:55:12
DB3011 reports ACTIVE alarm
Alarm: Stereo LOSS
Signal parameters:
RF: 6dBuV
Stereo: LOSS
FM Tuner Left: -15.9dBFs
FM Tuner Right: -15.9dBFs
Link: OK
IP Stream: OK
Stream Left: -12.3dBFs
Stream Right: -10.8dBFs