Status - Buffalo terastation 3000 User Manual

Hide thumbs Also See for terastation 3000:
Table of Contents

Advertisement

SYSTEM I10
A rise in the system temperature may have
exceeded the allowable safety value.
TOO HOT !
SYSTEM Error E11
An error occurred in the fan speed.
Fan Failure
SYSTEM Error E12
A rise in the system temperature may have
exceeded the allowable safety value.
Cooling Failure
RAID Arrayx E14
RAID array X cannot be mounted.
Can't Mount
HDx Error E16
Unable to find hard drive X.
HDx Not Found
HDx Error E22
Mounting of hard drive X failed.
HDx Can't Mount
FailOver E27
Unable to find the backup TeraStation.
LostBackupTarget
HDx Broken E30
An error occurred, so hard drive X was
removed from the RAID array.
Replace the DISK

Status

After you change settings or format a hard drive, the current status is displayed on the LCD.
LCD Message
HDx Warning I11
Bad Sectors
Operation I12
DEGRADE MODE
RAID I13
ARRAYxFormatting
RAID I14
ARRAYx Checking
RAID I15
ARRAYx Scanning
RAID I16
ARRAYx Creating
RAID I17
ARRAYx Resyncing
RAID I18
ARRAYx Rebuilding
Description
The bad sectors in hard drive X may
have reached a dangerous level.
Operating in degraded mode.
Formatting RAID array X.
Checking RAID array X.
Examining the error status of RAID
array X.
Creating RAID array X.
Resynchronizing RAID array X.
Rebuilding RAID array X.
Move the TeraStation to a cool location. Do
not place objects in the area around the
TeraStation.
Check that no foreign objects or dust are
clogging the fan. If any foreign objects or dust
are found, use a pair of tweezers, air duster,
or other tool to remove them. If the error is
displayed again, contact Buffalo technical
support for assistance.
Do not place objects in the area around the
TeraStation. Also, move the TeraStation to a
cool location.
Run the RAID array disk check in Settings.
Hard drive X may be disconnected or may
have failed. After shutting down, reinstall the
hard drive.
Format the hard drive. After formatting,
if the error still appears after rebooting,
replace the hard drive. If the error is displayed
again, contact Buffalo technical support for
assistance.
In the main TeraStation's settings, navigate to
Backup - Failover to reconfigure the backup
TeraStation for failover.
Replace hard drive X.
Corrective Action
Replace hard drive X.
-
-
-
-
-
-
-
173

Advertisement

Table of Contents
loading

Table of Contents