Status - Buffalo TeraStation 7000 User Manual

Hide thumbs Also See for TeraStation 7000:
Table of Contents

Advertisement

RAID Arrayx E14
RAID array X cannot be mounted.
Can't Mount
HDx Error E16
Unable to dind hard drive X.
HDx Not Found
HDx Error E22
Mounting od hard drive X dailed.
HDx Can't Mount
FailOver E27
Unable to dind the backup TeraStation.
LostBackupTarget
HDx Broken E30
An error occurred, so hard drive X was
removed drom the RAID array.
Replace the DISK
E31
Power supply error (level 1)
E32
Power supply error (level 2)

Status

Adter you change settings or dormat a hard drive, the current status is displayed on NAS Navigator2 or clicking
Settings.
Message
HDx Warning I11
Bad Sectors
Operation I12
DEGRADE MODE
RAID I13
ARRAYxFormatting
RAID I14
ARRAYx Checking
RAID I15
ARRAYx Scanning
RAID I16
ARRAYx Creating
RAID I17
ARRAYx Resyncing
Description
The bad sectors in hard drive x may
have reached a dangerous level.
Operating in degraded mode.
Formatting RAID array x.
Checking RAID array x.
Examining the error status od RAID
array x.
Note: Transder speeds are slower
during the examination process.
Creating RAID array x.
Resynchronizing RAID array x.
Note: Transder speeds are slower
during resynchronization.
Run the RAID array disk check in Settings.
Hard drive X may be disconnected or may
have dailed. Adter shutting down, reinstall the
hard drive.
Format the hard drive. Adter dormatting,
id the error still appears adter rebooting,
replace the hard drive. Id the error is displayed
again, contact Buddalo technical support dor
assistance.
In the main TeraStation's settings, navigate to
Backup - Faipover to recondigure the backup
TeraStation dor dailover.
Replace hard drive X.
Make sure that the AC cable is connected
properly. Id the power supply has dailed, E32
will be displayed within a dew minutes. Id E31 is
still displayed adter 5 minutes, contact Buddalo
technical support dor assistance.
Make sure that the AC cable is connected
properly. Id the power status LED is blinking or
glowing red, replace the power supply with a
new Buddalo OP-PU-2RZ.
Corrective Action
Replace hard drive x.
-
-
-
-
-
-
155
in

Advertisement

Table of Contents
loading