Status - Buffalo TeraStation 3000 User Manual

Hide thumbs Also See for TeraStation 3000:
Table of Contents

Advertisement

LCD Message
E10 UPS Running Off
Battery
E11 Fan Failure
E12 Cooling Failure
E14 Can't Mount
Arrayx
E16 Drivex Not
Found
E22 Can't Mount
Drivex
E27 Lost Failover
Target
E30 Replace Drivex

Status

After you change settings or format a drive, the current status is displayed on the LCD panel.
Note: The "x" in the LCD message is the number of the drive or array involved in the process.
LCD Message
I10 System Is
Overheating
I11 Bad Sectors on
Drivex
I12 Degraded Mode
I13 Formatting
Arrayx...
Description
The TeraStation is running on the UPS
battery due to a power outage.
If the setting to use the UPS connected to
this TeraStation has been configured, the
UPS cable may be disconnected.
If the setting to use the UPS connected to
another TeraStation on the same network
has been configured, the LAN cable of this
TeraStation may be disconnected.
An error occurred in the fan speed.
A rise in the system temperature may have
exceeded the allowable safety value.
The RAID array cannot be mounted.
Unable to find the drive.
Unable to mount the drive.
Unable to find the backup TeraStation.
An error occurred, so the drive was
removed from the RAID array.
Description
A rise in the system temperature may have
exceeded the allowable safety value.
The drive has too many bad sectors.
Operating in degraded mode.
Formatting the RAID array.
Corrective Action
Shut down the TeraStation safely and wait
until the power outage ends. If certain
settings are configured, the TeraStation
may shut down automatically when the
error is detected.
Verify that the UPS cable or LAN cable is
connected properly.
Check that no foreign objects or dust are
clogging the fan. If any foreign objects or
dust are found, use a pair of tweezers, air
duster, or other tool to remove them. If the
error is displayed again, contact Buffalo
technical support for assistance.
Do not place objects in the area around
the TeraStation. Also, move the TeraStation
to a cool location.
Run the RAID array disk check in Settings.
The drive may be disconnected or may
have failed. After shutting down, reinstall
the drive.
Format the drive. After formatting, if the
error still appears after rebooting, replace
the drive. If the error is displayed again,
contact Buffalo technical support for
assistance.
In the main TeraStation's Settings, navigate
to Backup > Failover to reconfigure the
backup TeraStation for failover.
Replace the drive.
Corrective Action
Move the TeraStation to a cool location. Do
not place objects in the area around the
TeraStation.
Replace the drive.
-
-
221

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ts3400dTs3400rTs3200dTs3200d6cc