When the replacement hard drive is recognized, the status LED will flash red and the message "Press FuncSW I31
New Disk x ready" will be displayed on the LCD panel.
7
Hold down the function button on the front of the TeraStation for 3 seconds until it beeps.
For RAID 1, 5, or 6:
The TeraStation will start rebuilding the RAID array automatically. After a few minutes, the message "RAID I18
ARRAYx Rebuilding" will be displayed until the drive is rebuilt.
For JBOD:
The drive will be formatted as an individual drive. Create a shared folder on the drive before use.
Drive Replacement (using a redundant RAID mode such as RAID 1, 5 or 6 with auto-
shutdown enabled)
This section describes the process of replacing a drive while
1
Open the front cover with the key.
2
Push the unlock button of the failed hard drive and swing the lock mechanism out.
3
Pull out the drive cartridge and remove it from the TeraStation.
the TeraStation is