Hammer Bank Power Cable Shorts Test - Printronix P5000 Maintenance Manual

Line matrix printers
Hide thumbs Also See for P5000:
Table of Contents

Advertisement

Hammer Bank Power Cable Shorts Test

This test determines if the hammer bank power cable is shorted.
1. Prepare the printer for maintenance (page 132).
2. Remove the paper path (page 199).
3. Disconnect hammer bank power cable connector P105 from J105 on the
4. Attach or hold the common lead (usually black) of an Ohmmeter to the
5. At the hammer bank power cable plug (P05) on the shuttle terminator
6. Disconnect the common meter lead from the shuttle frame.
7. Check the hammer bank power cable for shorts by checking pin-to-pin:
8. Connect hammer bank power cable connector P105 to J105 on the
9. Install the paper path (page 199).
10. Return the printer to normal operation (page 133).
Loading Through the Network Interface Card (NIC)
controller board. (See Figure 39, page 236, item 10.)
shuttle frame.
board, touch each of the 10 pins with the positive (usually red) meter lead
and test for shorts to ground. If you find any shorts to ground, replace the
hammer bank power cable.
touch pin 1 with one meter lead and pin 2 with the other meter lead. If
there is continuity, it means there is a short. (Continuity is defined as a
reading of less than 1 Ohm; in other words, very low resistance.) Repeat
this process until you have tested all the pins in the cable. If you find any
shorts, replace the cable.
controller board. (See Figure 39, page 236, item 10.)