b. Install and torque three screws to 20 ± 2 inch-pounds (2.26 ± 0.23
N•m).
15. Push the platen to the left.
16. Install the forms thickness lever on the right hand platen shaft, pressing
the interlock switch out of the way as the lever slides past it. Tighten the
7/64 inch setscrew. (See page 242.) Open and close the forms thickness
lever to make sure the setscrew does not touch the right ribbon guide.
17. Install the platen shaft pulley with the 7/64 inch setscrew facing up and
tighten the setscrew (page 242, items 21 and 22). Open and close the
forms thickness lever and check that the platen pulley setscrew does not
hit the left ribbon guide.
18. Install, but do not adjust, the platen open belt (page 242, item 23).
19. Install the paper ironer with the black tape towards the rear of the printer
(page 242, item 3).
20. Install the shuttle frame assembly (page 215).
21. Adjust the platen gap (page 140).
22. Adjust the platen open belt (page 136).
23. Check ribbon guide alignment (page 142).
24. Check the hammer phasing (page 148).
25. Return the printer to normal operation (page 133).