Configuration Manual
Ascom d62 DECT Handset
see
5.25.1 Call Predefined Number without Sending Alarm
• Text indication for alarm on multiple press
• Define multiple press
1,2
• ALS
• Silent alarm
If enabled, the indication of an alarm has been sent and received is disabled.
• Mode for automatic call after alarm
The call can be established in the following modes;
- Normal: the call is established as an ordinary call.
- Loudspeaking: the loudspeaker on the backside of the handset is turned on.
- Monitoring: a one-way speech channel is established, that is, the called part can only
listen to an conversation.
See also
5.24 Common Alarm Settings
Information about the handset's location can also be sent along with an alarm, see
Base station positioning
5.25.1 Call Predefined Number without Sending Alarm
It is possible to configure the push-button to dial the automatic call after alarm number
without sending an alarm. The following example describes how to configure the push-
button (alarm on long press). The corresponding settings can also be configured for the
push-button when it is pressed twice or more (alarm on multiple press).
Example of configuration:
1
Select Alarm > Common
2
In the Number for automatic call after alarm field, enter the number to be dialed.
3
Select Alarm > Alarm on long press
4
In the Alarm type for long press drop-down list, select "Not used".
5
In the Mode for automatic call after alarm drop-down list, select one of the following:
- Normal: the call is established as an ordinary call.
- Loudspeaking: the loudspeaker on the backside of the handset is turned on.
- Monitoring: a one-way speech channel is established, that is, the called part can only
listen to an conversation.
This configuration makes it possible to long press the push-button to dial the number
without sending an alarm. However, the push-button can be configured to send an alarm by
pressing it twice (see Alarm type for multiple press in chapter
on page 32).
Information about the handset's location can also be sent along with an alarm, see
Base station positioning
1. If the parameters "ALS" and "Silent alarm" are set, no ALS will be triggered after an alarm has been sent.
2. The ALS will not be activated if an automatic call is established after an alarm has been sent.
25 November 2011 / Ver. E
1
on page 32 for additional parameter settings.
on page 28 and
on page 28 and
on page 33.
5.19 DECT Location
on page 29.
5.24 Common Alarm Settings
5.19 DECT Location
on page 29.
TD 92639EN