NEC EXPRESS 320Lb User Manual page 147

Nec server user's guide
Hide thumbs Also See for EXPRESS 320Lb:
Table of Contents

Advertisement

STATUS LED
Error Message
Color
State
CPU2 offline
Green Blink
CPU2 removed
Green Blink
CPU2 Temp Alm
Amber Blink
00
CPU2 Temp Alm
Amber Lit
02
CPU2 Temp Alm
Amber Blink
07
CPU2 Temp Alm
Amber Lit
09
CPU2 VccpAlm
Amber Blink
00
CPU2 VccpAlm
Amber Lit
02
CPU2 VccpAlm
Amber Blink
07
CPU2 VccpAlm
Amber Lit
09
CPU2 VttAlm 00 Amber Blink
CPU2 VttAlm 02 Amber Lit
CPU2 VttAlm 07 Amber Blink
CPU2 VttAlm 09 Amber Lit
CPU20 TempAlm
Amber Blink
00
CPU20 TempAlm
Amber Lit
02
CPU20 TempAlm
Amber Blink
07
CPU20 TempAlm
Amber Lit
09
CPU21 TempAlm
Amber Blink
00
CPU21 TempAlm
Amber Lit
02
CPU21 TempAlm
Amber Blink
07
CPU21 TempAlm
Amber Lit
09
5-24 Problem Solving
Suspected
Description
module
CPU module #2
The CPU module has been
logically disconnected.
CPU module #2
The CPU module has come
off.
CPU module #2
Temperature alarm (lower
limit)
CPU module #2
Fatal temperature alarm
(lower limit)
CPU module #2
Temperature alarm (upper
limit)
CPU module #2
Fatal temperature alarm
(upper limit)
CPU module #2
CPU operating voltage alarm
(lower limit) (VCCP)
CPU module #2
Fatal CPU operating voltage
alarm (lower limit) (VCCP)
CPU module #2
CPU operating voltage alarm
(upper limit) (VCCP)
CPU module #2
Fatal CPU operating voltage
alarm (upper limit) (VCCP)
CPU module #2
1.25-V power voltage alarm
(lower limit)
CPU module #2
Fatal 1.25-V power voltage
alarm (lower limit)
CPU module #2
1.25-V power voltage alarm
(upper limit)
CPU module #2
Fatal 1.25-V power voltage
alarm (upper limit)
CPU module #2
CPU#1 temperature alarm
(lower limit)
CPU module #2
Fatal CPU#1 temperature
alarm (lower limit)
CPU module #2
CPU#1 temperature alarm
(upper limit)
CPU module #2
Fatal CPU#1 temperature
alarm (upper limit)
CPU module #2
CPU#2 temperature alarm
(lower limit)
CPU module #2
Fatal CPU#2 temperature
alarm (lower limit)
CPU module #2
CPU#2 temperature alarm
(upper limit)
CPU module #2
Fatal CPU#2 temperature
alarm (upper limit)
Procedure
Start the PCI module by
ft sever utility or
dismount and remount
that module. If not
solved by the above,
contact your sales
agent.
Dismount and remount
the PCI module. If not
solved by the above,
contact your sales
agent.
Check to see if dust is
accumulated on the
internal fans. Check also
if the fan cables are
connected securely. If
not solved by the above,
contact your sales
agent.
Contact your sales
agent.
Check to see if dust is
accumulated on the
internal fans. Check also
if the fan cables are
connected securely. If
not solved by the above,
contact your sales
agent.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express 320lb-rExpress5800/320lbExpress5800/320lb-r

Table of Contents