STATUS LED
Error Message
Color
= A =
= A =
= A =
= A =
AmbientTempAlm00 Amber
AmbientTempAlm02 Amber
AmbientTempAlm07 Amber
AmbientTempAlm09 Amber
= B =
= B =
= B =
= B =
BMC Unsync
-
BMC0 Not Ready
Green
BMC1 Not Ready
Green
= C =
= C =
= C =
= C =
Cor0 +12vAlm 00
Amber
Cor0 +12vAlm 02
Amber
Cor0 +12vAlm 07
Amber
Cor0 +12vAlm 09
Amber
Cor0 +2.5vAlm 00 Amber
Cor0 +2.5vAlm 02 Amber
Cor0 +2.5vAlm 07 Amber
Cor0 +2.5vAlm 09 Amber
Cor0 +3.3vAlm 00 Amber
Cor0 +3.3vAlm 02 Amber
Cor0 +3.3vAlm 07 Amber
Cor0 +3.3vAlm 09 Amber
Cor0 +3.3vsAlm
Amber
00
Cor0 +3.3vsAlm
Amber
02
Cor0 +3.3vsAlm
Amber
07
Cor0 +3.3vsAlm
Amber
09
Cor0 +5.0vAlm 00 Amber
Cor0 +5.0vAlm 02 Amber
Cor0 +5.0vAlm 07 Amber
Suspected module
State
Blink CPU module
Lit
CPU module
Blink CPU module
Lit
CPU module
-
PCI module #1
Blink PCI module #1
Blink PCI module #2
Blink PCI module #1
Lit
PCI module #1
Blink PCI module #1
Lit
PCI module #1
Blink PCI module #1
Lit
PCI module #1
Blink PCI module #1
Lit
PCI module #1
Blink PCI module #1
Lit
PCI module #1
Blink PCI module #1
Lit
PCI module #1
Blink PCI module #1
Lit
PCI module #1
Blink PCI module #1
Lit
PCI module #1
Blink PCI module #1
Lit
PCI module #1
Blink PCI module #1
Description
Temperature alarm (lower limit)
Fatal temperature alarm (lower
limit)
Temperature alarm (upper limit)
Fatal temperature alarm (upper
limit)
The BMC cannot be synchronized. Contact your sales agent.
PCI module's BMC is disconnected If disconnection continues for a
12-V power voltage alarm (lower
limit)
Fatal 12-V power voltage alarm
(lower limit)
12-V power voltage alarm (upper
limit)
Fatal 12-V power voltage alarm
(upper limit)
2.5-V power voltage alarm (lower
limit)
Fatal 2.5-V power voltage alarm
(lower limit)
2.5-V power voltage alarm (upper
limit)
Fatal 2.5-V power voltage alarm
(upper limit)
3.3-V power voltage alarm (lower
limit)
Fatal 3.3-V power voltage alarm
(lower limit)
3.3-V power voltage alarm (upper
limit)
Fatal 3.3-V power voltage alarm
(upper limit)
3.3-V power voltage alarm (lower
limit)
Fatal 3.3-V power voltage alarm
(lower limit)
3.3-V power voltage alarm (upper
limit)
Fatal 3.3-V power voltage alarm
(upper limit)
5-V power voltage alarm (lower
limit)
Fatal 5-V power voltage alarm
(lower limit)
5-V power voltage alarm (upper
limit)
Procedure
Contact your sales agent.
while, contact your sales agent.
Contact your sales agent.
Contact your sales agent.