NEC EXPRESS 320Lb User Manual page 140

Nec server user's guide
Hide thumbs Also See for EXPRESS 320Lb:
Table of Contents

Advertisement

STATUS LED
Error Message
Color
Cor0 -12vAlm 09
Amber
Cor0 Bus PERR 01
Green
Cor0 Bus SERR 01
Green
Cor0 CLK Alm 00
Amber
Cor0 CLK Alm 02
Amber
Cor0 CLK Alm 07
Amber
Cor0 CLK Alm 09
Amber
Cor0 FAN Alm 01
Amber
Cor0 FAN Alm 02
Amber
Cor0 FAN Alm 03
Amber
Cor0 FAN Alm 04
Amber
Cor0 FAN Alm 05
Amber
Cor0 offline
Green
Cor0 removed
Green
Cor0 Temp Alm 00 Amber
Cor0 Temp Alm 02 Amber
Cor0 Temp Alm 07 Amber
Cor0 Temp Alm 09 Amber
Cor1 +12vAlm 00
Amber
Cor1 +12vAlm 02
Amber
Cor1 +12vAlm 07
Amber
Cor1 +12vAlm 09
Amber
Cor1 +2.5vAlm 00 Amber
Cor1 +2.5vAlm 02 Amber
Cor1 +2.5vAlm 07 Amber
Cor1 +2.5vAlm 09 Amber
Cor1 +3.3vAlm 00 Amber
Suspected module
State
Lit
PCI module #1
Blink PCI module #1
Blink PCI module #1
Blink CLOCK board
Lit
CLOCK board
Blink CLOCK board
Lit
CLOCK board
Blink PCI module #1
Blink PCI module #1
Blink PCI module #1
Blink PCI module #1
Blink PCI module #1
Blink PCI module #1
Blink PCI module #1
Blink PCI module #1
Lit
PCI module #1
Blink PCI module #1
Lit
PCI module #1
Blink PCI module #2
Lit
PCI module #2
Blink PCI module #2
Lit
PCI module #2
Blink PCI module #2
Lit
PCI module #2
Blink PCI module #2
Lit
PCI module #2
Blink PCI module #2
Description
Fatal -12-V power voltage alarm
(upper limit)
PCI bus parity error
Fatal PCI bus error
Clock alarm (lower limit)
Fatal Clock alarm (lower limit)
Clock alarm (upper limit)
Fatal Clock alarm (upper limit)
Cooling fan1 alarm
Cooling fan2 alarm
Cooling fan3 alarm
Cooling fan4 alarm
Cooling fan5 alarm
PCI module logically isolated
PCI module detached
Temperature alarm (lower limit)
Fatal temperature alarm (lower
limit)
Temperature alarm (upper limit)
Fatal temperature alarm (upper
limit)
12-V power voltage alarm (lower
limit)
Fatal 12-V power voltage alarm
(lower limit)
12-V power voltage alarm (upper
limit)
Fatal 12-V power voltage alarm
(upper limit)
2.5-V power voltage alarm (lower
limit)
Fatal 2.5-V power voltage alarm
(lower limit)
2.5-V power voltage alarm (upper
limit)
Fatal 2.5-V power voltage alarm
(upper limit)
3.3-V power voltage alarm (lower
limit)
Procedure
Contact your sales agent.
Check to see if dust is
accumulated on the internal
fans. Check also if the fan
cables are connected securely.
If not solved by the above,
contact your sales agent.
Start the PCI module by ft sever
utility or dismount and remount
that module. If not solved by the
above, contact your sales agent.
Dismount and remount the PCI
module. If not solved by the
above, contact your sales agent.
Check to see if dust is
accumulated on the internal
fans. Check also if the fan
cables are connected securely.
If not solved by the above,
contact your sales agent.
Contact your sales agent.
Problem Solving 5-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express 320lb-rExpress5800/320lbExpress5800/320lb-r

Table of Contents