SCXI-1163 Cabling
Front Panel
Connector
Front Panel

SCXI-1302 50-Pin Terminal Block

The SCXI-1302 terminal block has screw terminal connections for the 50-pin connector on the
SCXI-1180 feedthrough panel.

SCXI-1302 Wiring Procedure

To wire the SCXI-1302 terminal block, you must remove the cover, connect all the wiring, and
replace the cover. The procedure for this is as follows:
1. Unscrew the rear grounding screw on the back of the terminal block, as shown in Figure E-5.
2. With a flathead screwdriver, carefully pry the cover off the terminal block.
3. Insert each wire through the terminal block strain relief.
4. Connect the wires to the screw terminals.
5. Tighten the large strain relief screws to secure the wires.
6. Snap the cover back in place.
7. Reinsert the rear grounding screw. The terminal block is now ready to be connected to the
front panel connector.
SCXI-1163 User Manual
Ribbon Cable to
Rear and Breakout
Connectors
Step 5
Front Threaded Strip

Figure E-4. SCXI-1180 Front Panel Installation

E-14