Matrox Meteor-II Installation And Hardware Reference Manual page 52

Hide thumbs Also See for Meteor-II:
Table of Contents

Advertisement

52 Appendix B: Technical information
• Input signals in TTL format:
- No termination.
- Input current: ± 1µA.
- Input voltage:
Max of low: 0.8 V.
Min of high: 2 V.
Range: -0.5 V to 5.5 V.
• Output signals in TTL format:
- No termination.
- Output current:
Max of low: -60 mA.
Min of high: 30 mA.
- Output voltage:
Max of low: 0.55 V.
Min of high: 2 V.