HP P2000 G3 MSA Reference Manual page 55

Hide thumbs Also See for P2000 G3 MSA:
Table of Contents

Advertisement

451
Info.
A remote volume's status changed from offline to online.
Recommended actions
No action is required.
452
Info.
The indicated volume has been detached from the indicated replication set.
The volume can now be physically moved to another storage system.
Recommended actions
No action is required.
453
Info.
The indicated volume has been reattached to the indicated replication set.
Recommended actions
No action is required.
454
Info.
A user changed the drive-spin-down delay for the indicated vdisk to the indicated value.
Recommended actions
No action is required.
455
Warning
The controller detected that the configured host-port link speed exceeded the capability of an FC SFP. The
speed has been automatically reduced to the maximum value supported by all hardware components in
the data path.
Recommended actions
Replace the SFP in the indicated port with an SFP that supports a higher speed.
456
Warning
The system's IQN was generated from the default OUI because the controllers could not read the OUI from
the midplane FRU ID data during startup. If the IQN is wrong for the system's branding, iSCSI hosts might
be unable to access the system.
Recommended actions
If event 270 with status code 0 is logged at approximately the same time, restart the controllers.
464
Warning
A user inserted an unsupported cable or SFP into the indicated controller host port.
Recommended actions
Replace the cable or SFP with a supported type, as specified in your product's User Guide.
465
Info.
A user removed an unsupported cable or SFP from the indicated controller host port.
Recommended actions
No action is required.