156
Warning
The Management Controller has been restarted from the Storage Controller for the purpose of error
recovery.
Recommended actions
•
See the recommended actions for event 152, which is logged at approximately the same time.
Info.
The Management Controller has been restarted from the Storage Controller in a normal case, such as
when initiated by a user.
Recommended actions
•
No action is required.
157
Error
A failure occurred when trying to write to the Storage Controller flash chip.
Recommended actions
•
Replace the controller module that logged this event.
158
Info.
A correctable ECC error occurred in the CPU memory.
Recommended actions
•
No action is required.
161
Info.
One or more enclosures do not have a valid path to an enclosure management processor (EMP).
All enclosure EMPs are disabled.
Recommended actions
•
See "Resources for diagnosing and resolving problems" in the SMU help for the System Events panel,
or the CLI help for the show events command.
162
Warning
The host WWNs (node and port) previously presented by this controller module are unknown. In a
dual-controller system this event has two possible causes:
•
One or both controller modules have been replaced or moved while the system was powered off.
•
One or both controller modules have had their flash configuration cleared (this is where the previously
used WWNs are stored).
The controller module recovers from this situation by generating a WWN based on its own serial number.
Recommended actions
•
If the controller was replaced or someone reprogrammed its FRU ID data, verify the WWN information
for this controller module on all hosts that access it.