HP P2000 G3 MSA Reference Manual page 34

Hide thumbs Also See for P2000 G3 MSA:
Table of Contents

Advertisement

213
Info.
The indicated standard volume has been converted to a master volume, or the indicated master volume has
been converted to a standard volume.
Recommended actions
No action is required.
214
Info.
The creation of snapshots is complete. The number of snapshots is indicated.
Additional events give more information for each snapshot.
Recommended actions
No action is required.
215
Info.
A previously created batch of snapshots is now committed and ready for use. The number of snapshots is
indicated.
Additional events give more information for each snapshot.
Recommended actions
No action is required.
217
Error
A super-capacitor failure occurred on the controller.
Recommended actions
Replace the controller module that logged this event.
218
Warning
The super-capacitor pack is near end of life.
Recommended actions
Replace the controller module reporting this event.
219
Info.
Utility priority has been changed by a user.
Recommended actions
No action is required.
220
Info.
Rollback of data in the indicated master volume to data in the indicated snapshot has been started by a
user.
Recommended actions
No action is required.
221
Info.
Snapshot reset has completed.
Recommended actions
No action is required.
34
Event descriptions

Advertisement

Table of Contents
loading

Table of Contents