19
Info.
A rescan has completed.
Recommended actions
No action is required.
20
Info.
Storage Controller firmware update has completed.
Recommended actions
No action is required.
21
Error
Vdisk verification completed. Errors were found but not corrected.
Recommended actions
Perform a vdisk scrub to find and correct the errors.
Warning
Vdisk verification did not complete because of an internally detected condition such as a failed disk.
If a disk fails, data may be at risk.
Recommended actions
Resolve any non-disk hardware problems, such as a cooling problem or a faulty controller module,
expansion module, or power supply.
Check whether any disks in the vdisk have logged SMART events or unrecoverable read errors.
• If so, and the vdisk is a non-redundant RAID level (RAID 0 or non-RAID), copy the data to a different
vdisk and replace the faulty disks.
• If so, and the vdisk is a redundant RAID level, replace the faulty disks. Before replacing a disk,
confirm that a reconstruction is not currently running on the vdisk. It is also recommended to make a
full backup of all the data on the vdisk before replacing disks. If more than one disk in the vdisk has
errors, replace the disks one at a time and allow reconstruction to complete after each disk is
replaced.
Info.
Vdisk verification failed immediately, was aborted by a user, or succeeded.
Recommended actions
No action is required.
23
Info.
Vdisk creation has started.
Recommended actions
No action is required.
25
Info.
The statistics for the indicated vdisk have been reset.
Recommended actions
No action is required.
27
Info.
Cache parameters have been changed for the indicated vdisk.
Recommended actions
No action is required.