19
Info.
A rescan has completed.
Recommended actions
•
No action is required.
20
Info.
Storage Controller firmware update has completed.
Recommended actions
•
No action is required.
21
Error
Vdisk verification completed. Errors were found but not corrected.
Recommended actions
•
Perform a vdisk scrub to find and correct the errors.
Warning
Vdisk verification did not complete because of an internally detected condition such as a failed disk.
If a disk fails, data may be at risk.
Recommended actions
•
Resolve any non-disk hardware problems, such as a cooling problem or a faulty controller module,
expansion module, or power supply.
•
Check whether any disks in the vdisk have logged SMART events or unrecoverable read errors.
• If so, and the vdisk is a non-redundant RAID level (RAID 0 or non-RAID), copy the data to a different
vdisk and replace the faulty disks.
• If so, and the vdisk is a redundant RAID level, replace the faulty disks. Before replacing a disk,
confirm that a reconstruction is not currently running on the vdisk. It is also recommended to make a
full backup of all the data on the vdisk before replacing disks. If more than one disk in the vdisk has
errors, replace the disks one at a time and allow reconstruction to complete after each disk is
replaced.
Info.
Vdisk verification failed immediately, was aborted by a user, or succeeded.
Recommended actions
•
No action is required.
23
Info.
Vdisk creation has started.
Recommended actions
•
No action is required.
25
Info.
The statistics for the indicated vdisk have been reset.
Recommended actions
•
No action is required.
27
Info.
Cache parameters have been changed for the indicated vdisk.
Recommended actions
•
No action is required.
12