HP P2000 G3 MSA Reference Manual page 28

Hide thumbs Also See for P2000 G3 MSA:
Table of Contents

Advertisement

177
Info.
Cache data were purged for the indicated missing volume.
Recommended actions
No action is required.
181
Info.
One or more configuration parameters associated with the Management Controller have been changed,
such as configuration for SNMP, SMI-S, email notification, and system strings (system name, system
location, etc.).
Recommended actions
No action is required.
182
Info.
All disk channels have been paused. I/O will not be performed on the disks until all channels are
unpaused.
Recommended actions
If this event occurs in relation to disk firmware update, no action is required. When the condition is
cleared, event 183 is logged.
If this event occurs and you are not performing disk firmware update, see "Resources for diagnosing
and resolving problems" in the SMU help for the System Events panel, or the CLI help for the show
events command.
183
Info.
All disk channels have been unpaused, meaning that I/O can resume. An unpause initiates a rescan,
which when complete is logged as event 19.
This event indicates that the pause reported by event 182 has ended.
Recommended actions
No action is required.
185
Info.
An enclosure management processor (EMP) write command has completed.
Recommended actions
No action is required.
186
Info.
Enclosure parameters have been changed by a user.
Recommended actions
No action is required.
187
Info.
The write-back cache has been enabled.
Event 188 is the corresponding event that is logged when write-back cash is disabled.
Recommended actions
No action is required.
28
Event descriptions

Advertisement

Table of Contents
loading

Table of Contents