Event Descriptions - HP P2000 G3 MSA Reference Manual

Hide thumbs Also See for P2000 G3 MSA:
Table of Contents

Advertisement

Event descriptions

1
Warning
If the indicated vdisk is RAID 6, it is operating with degraded health due to the failure of two disks.
If the indicated vdisk is not RAID 6, it is operating with degraded health due to the failure of one disk.
The vdisk is online but cannot tolerate another disk failure.
If a dedicated spare or global spare of the proper type and size is present, that spare is used to
automatically reconstruct the vdisk; events 9 and 37 are logged to indicate this. If no usable spare disk is
present, but an available disk of the proper type and size is present and the dynamic spares feature is
enabled, that disk is used to automatically reconstruct the vdisk; event 37 is logged.
Recommended actions
If a spare of the proper type and size is present, or if the dynamic spares feature is enabled,
reconstruction automatically starts and event 37 is logged. Replace the failed disk and configure the
replacement as a dedicated or global spare for future use.
If no spare is present and the dynamic spares feature is disabled (that is, event 37 is NOT logged),
configure an available disk as a dedicated spare for the vdisk or replace the failed disk and configure
the new disk as a dedicated spare for the vdisk. That spare is used to automatically reconstruct the
vdisk; confirm this by checking that events 9 and 37 are logged.
If the replacement disk was previously used in another vdisk and has a status of leftover (LEFTOVR),
clear the disk's metadata so you can assign the disk as a spare.
Confirm that all failed disks have been replaced and that there are sufficient spare disks configured for
future use.
3
Error
The indicated vdisk went offline.
One disk failed for RAID 0 or NRAID, three disks failed for RAID 6, or two disks failed for other RAID
levels. The vdisk cannot be reconstructed.
Recommended actions
The CLI trust command may be able to recover some or all of the data on the vdisk
4
Info.
The indicated disk had an uncorrectable error and the controller reassigned the indicated block.
Recommended actions
Monitor the error trend and whether the number of errors approaches the total number of bad-block
replacements available.
6
Warning
Vdisk creation failed during initialization.
Recommended actions
Compare the vdisk count with the configuration limit for the maximum number of vdisks.
• If you reached this limit, either purchase additional storage or remove unneeded vdisks.
• If you have not reached the limit, see "Resources for diagnosing and resolving problems" in the
SMU help for the System Events panel, or the CLI help for the show events command.
Recommended actions
Info.
No action is required.