HP P2000 G3 MSA Reference Manual page 14

Hide thumbs Also See for P2000 G3 MSA:
Table of Contents

Advertisement

40
Error
The sensors monitored a temperature or voltage in the failure range.
Recommended actions
Check that the storage system's fans are running.
Check that the ambient temperature is not too warm. The enclosure operating range is 5–40 C
(41 F–104 F).
Check that there is a module or blank plate in every module slot in the enclosure.
If none of the above explanations apply, replace the controller module that reported the error.
When the problem is fixed, event 47 is logged.
41
Info.
The indicated disk has been designated a spare for the indicated vdisk.
Recommended actions
No action is required.
43
Info.
The indicated vdisk has been deleted.
Recommended actions
No action is required.
44
Warning
The controller contains cache data for the indicated volume but the corresponding vdisk is not online.
Recommended actions
Determine the reason why the disks comprising the vdisk are not online.
If an enclosure is down, determine corrective action.
If the vdisk is no longer needed, you can clear the orphan data; this will result in lost data.
If the volume is missing and was not intentionally removed, see "Resources for diagnosing and
resolving problems" in the SMU help for the System Events panel, or the CLI help for the show events
command.
47
Info.
An error detected by the sensors has been cleared. This event indicates that a problem reported by event
39 or 40 is resolved.
Recommended actions
No action is required.
48
Info.
The indicated vdisk has been renamed.
Recommended actions
No action is required.
49
Info.
A lengthy SCSI maintenance command has completed. Output indicates whether it completed successfully
or a failure occurred. (This typically occurs during disk firmware update.)
Recommended actions
No action is required.
14
Event descriptions

Advertisement

Table of Contents
loading

Table of Contents