152
Warning
The Management Controller has not communicated with the Storage Controller (SC) for 15 minutes and
may have failed.
This event is initially logged as Informational severity. If the problem persists, this event is logged a second
time as Warning severity and the MC is automatically restarted in an attempt to recover from the problem.
Event 156 is then logged.
Recommended actions
•
If this event is logged only one time as Warning severity, no action is required.
•
If this event is logged more than one time as Warning severity, do the following:
• If you are now able to access the management interfaces of the controller that logged this event, do
the following:
• Check the version of the controller firmware and update to the latest firmware if needed.
• If the latest firmware is already installed, the controller module that logged this event probably
has a hardware fault. Replace the module.
• If you are not able to access the management interfaces of the controller that logged this event, do
the following:
• Shut down that controller and reseat the module.
• If you are then able to access the management interfaces, check the version of the controller
firmware and update to the latest firmware if needed.
• If the problem recurs, replace the module.
Info.
The Management Controller has not communicated with the Storage Controller for 160 seconds.
If communication is restored in less than 15 minutes, event 153 is logged. If the problem persists, this event
is logged a second time as Warning severity.
NOTE:
It is normal for this event to be logged as Informational severity during firmware update.
Recommended actions
•
Check the version of the controller firmware and update to the latest firmware if needed.
•
If the latest firmware is already installed, no action is required.
153
Info.
The Management Controller has re-established communication with the Storage Controller.
Recommended actions
•
No action is required.
154
Info.
New firmware has been loaded on the Management Controller (MC).
Recommended actions
•
No action is required.
155
Info.
New loader firmware has been loaded on the Management Controller (MC).
Recommended actions
•
No action is required.
HP P2000 G3 MSA System Event Descriptions Reference Guide
23