HP P2000 G3 MSA Reference Manual page 27

Hide thumbs Also See for P2000 G3 MSA:
Table of Contents

Advertisement

170
Info.
The last rescan detected that the indicated enclosure was added to the system.
Recommended actions
No action is required.
171
Info.
The last rescan detected that the indicated enclosure was removed from the system.
Recommended actions
No action is required.
172
Warning
The indicated vdisk has been quarantined because not all of its disks are available. There are not enough
disks to be fault tolerant. The partial vdisk will be held in quarantine until it becomes fault tolerant.
Recommended actions
Ensure that all disks are latched into their slots and have power.
During quarantine, the vdisk is not visible to the host. If after latching disks into their slots and powering
up the vdisk, the vdisk is still quarantined, you can manually remove the vdisk from quarantine so that
the host can see the vdisk. The vdisk is still critical.
If disks have failed, replace them.
When the vdisk has been removed from quarantine, event 173 is logged.
173
Info.
The indicated vdisk has been removed from quarantine.
Recommended actions
No action is required.
174
Info.
Enclosure or disk firmware update has succeeded, been aborted by a user, or failed.
If the firmware update fails, the user will be notified about the problem immediately and should take care
of the problem at that time, so even when there is a failure, this event is logged as Informational severity.
Recommended actions
No action is required.
175
Info.
An Ethernet link has changed status (up/down).
Recommended actions
Monitor the error trend. If this event occurs more than 8 times per hour, it should be investigated
This event is probably caused by equipment outside of the storage system, such as faulty cabling or a
faulty Ethernet switch.
If this event is being logged by only one controller in a dual-controller system, swap the Ethernet cables
between the two controllers. This will show whether the problem is outside or inside the storage system.
If the problem is not outside of the storage system, replace the controller module that logged this event.
176
Info.
The error statistics for the indicated disk have been reset.
Recommended actions
No action is required.
HP P2000 G3 MSA System Event Descriptions Reference Guide
27