PROGRAMMABLE PARAMETERS EXCLUSIVE GREEN HE C.S.I.
PARAMETERS DESCRIPTION
N.
PAR.
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
1
MINOR PARAMETER
2
INSULATION LEVEL OF BUILDING
3
10
DHW MODE
11
DHW CIRCUIT MAXIMUM SET-POINT
12
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
13
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
14
HEATING MODE
20
HEATING CIRCUIT MAXIMUM SET-POINT
21
MINIMUM HEATING SET POINT
22
MAXIMUM HEATING VENTILATOR SPEED
23
MINIMUM HEATING VENTILATOR SPEED
24
DIFFERENTIAL HEATING POSITIVE
25
DIFFERENTIAL HEATING NEGATIVE
26
MAX HEATING POWER REDUCTION TIMER
28
FORCED HEATING SHUT DOWN TIMER
29
HEATING TIMER RESET FUNCTION
30
31
MAXIMUM HEATING SET POINT 2CH (II circuit)
32
MINIMUM HEATING SET POINT 2CH (II circuit)
40
DHW THERMOSTAT OPERATING MODE
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
41
S.A.R.A. FUNCTION
42
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
43
THERMOREGULATION FUNCTION
44
45
INCLINATION THERMOREGULATION CURVE (OTC)
46
THERMOREGULATION FUNCTION 2CH
INCLINATION THERMOREGULATION CURVE (OTC) 2CH
47
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
48
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
50
HEAT REQUEST TYPE CH1 (I circuit)
51
HEAT REQUEST TYPE CH2 (II circuit)
52
DHW ANTIFREEZE FUNCTION TEMPERATURE (ON)
61
HEATING ANTIFREEZE FUNC. DELIVERY TEMP. (ON)
62
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
63
EXTERNAL SENSOR REACTIVITY
65
SEMI-AUTOMATIC FILLING
85
AUTOMATIC FILLING PRESSURE (ON)
86
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
87
ADJUSTABLE SPEED PUMP
90
ENABLE POST-CIRCULATION FROM DHW TO HEATING
92
DURATION OF POST-CIRCULATION FROM DHW TO HEATING
93
94
PUMP IN CONTINUAL MODE CH1 (CIRCUIT 1)
95
PUMP IN CONTINUAL MODE CH2 (CIRCUIT 2)
* The value is expressed on the display in revs/min/100 (example 3.600 = 36).
Some default values could be different from the one in the table, dependent on the status of data sheet updating
1 Setted in factory
2 Settede by technical assistance
UNIT OF
MIN
MEASURE
10-16-20-26-30-34-50-70
min
5
1 - Instantaneous
2 - Mini-tank
3 - External water- tank with thermostat
4 - External water- tank with sensor
5 - DS integrated water tank
6 3S integrated water tank
°C
40
0 - OFF
1 - ON
2 - Zone valves + remote control panel
3 - CONNECT AP
4 - Not used
5 - Not used
6 - CONNECT AT/BT
7 REMOTE CO NTROL+CONNECT AT/BT
8 REMOTE PANEL + ZONE VALVES
°C
40
C
20
revs/min
25 kW 60
35 kW 60
G20
G31
revs/min
25 kW
12
19
35 kW
12
19
°C
2
°C
2
min
0
min
0
-
0 (NO)
°C
40
°C
20
0 - OFF
1 - AUTO
2 - ON
0 - OFF
1 - AUTO
0 - OFF
1 - AUTO
2,5
0 - OFF
-
1 - AUTO
2,5
-
-
0
-
0
°C
0
°C
0
0 (very fast)
255 (very slow)
0 - Disabled
1 - Enabled
bar
0.4
0
0
1
0
0
MAX
DEFAULT
PARAMETERS
(1)
1
26 (25kW)-34 (35kW)
5
20
1
60
60
60
80
5
1
80
80
20
39
MAX
G20
G31
60
59
MIN
6
10
6
10
15
20
5
20
0
1 (YES)
80
45
39
25
1
1
1
1
1
20
40
1
10
40
-
1
0
1
0
1
4
10
6
10
6
20
1
0.6
1.0
-
41
100
0
1
5
255
0
1
1
0
ENGLISH