Programmable Parameters - Beretta EXCLUSIVE GREEN HE 25 B.S.I. Installer And User Manual

Hide thumbs Also See for EXCLUSIVE GREEN HE 25 B.S.I.:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 5
EXCLUSIVE BOILER GREEN HE B.S.I.

Programmable parameters

DESCRIPTION PARAMETERS
PAR.
1
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
2
THIS PARAMETER IS NOT infl uential
3
INSULATION LEVEL OF BUILDING
10
DHW MODE
11
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
12
WATER TANK MAXIMUM SET-POINT
13
DELIVERY TERMPERATURE EXT. WATER TANK
14
DELTA EXTERNAL WATER TANK (ON)
20
HEATING MODE
21
HEATING CIRCUIT MAXIMUM SET-POINT
22
MINIMUM HEATING SET POINT
23
MAXIMUM HEATING VENTILATOR SPEED
24
MINIMUM HEATING VENTILATOR SPEED
25
DIFFERENTIAL HEATING POSITIVE
26
DIFFERENTIAL HEATING NEGATIVE
28
MAX HEATING POWER REDUCTION TIMER
29
FORCED HEATING SHUT DOWN TIMER
30
HEATING TIMER RESET FUNCTION
31
MAXIMUM HEATING SET POINT 2CH (II circuit)
32
MINIMUM HEATING SET POINT 2CH (II circuit)
40
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
41
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
42
S.A.R.A. FUNCTION
43
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
44
THERMOREGULATION FUNCTION
45
INCLINATION THERMOREGULATION CURVE (OTC)
46
THERMOREGULATION FUNCTION 2CH
47
INCLINATION
THERMOREGULATION
(OTC) 2CH
48
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
50
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
51
HEAT REQUEST TYPE CH1 (I circuit)
52
HEAT REQUEST TYPE CH2 (II circuit)
61
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
62
HEATING ANTIFREEZE FUNC. DELIVERY TEMP.
(ON)
63
WATER TANK ANTIFREEZE FUNC. DELIV. TEMP.
(ON)
65
EXTERNAL SENSOR REACTIVITY
85
SEMI-AUTOMATIC FILLING
86
AUTOMATIC FILLING PRESSURE (ON)
18
UNIT OF
MEASURE
10*-16-20*-26-30-34-50*-70*
min
1 (Instantaneous)
2 (Mini-tank)
3 (External water-tank with thermostat)
4 (External water-tank with sensor)
5 (Integrated water tank)
° C
°C
°C
2 (not used)
3 (CONNECT AP)
4 (not used)
5 (not used)
6 (CONNECT AT/BT)
° C
°C
revs/min
revs/min
25kW 12** 19**
35kW 12** 19**
°C
°C
min
min
-
0 (NO)
°C
°C
1 (AUTO)
1 (AUTO)
-
1 (AUTO)
CURVE
-
-
-
°C
°C
0 (very fast)
0 (disabled)
1 (enabled)
bar
MIN
MAX
5
20
0 (OFF)
40
80
50
85
0
10
0 (OFF)
1 (ON)
40
80
20
39
G20 G31
25kW 60** 60**
35kW 60** 59**
G20 G31
2
10
2
10
0
20
0
20
1 (YES)
40
80
20
39
0 (OFF)
0 (OFF)
2,5
40
0 (OFF)
2,5
40
0
1
0
1
0
10
0
10
255 (very slow)
0,4
1,0
DEFAULT
PARAMETERS
(setted in
(setted by techn.
factory)
assist. centre)
1
26 (25kW)
34 (35kW)
5
5
60
60
80
5
1
80
20
MAX
MIN
6
6
15
5
0
45
25
1
1
1
1
1
20
1
10
-
1
0
0
4
6
6
20
1
0,6