b. Start the generator.
■ The DC receptacle may be used while the AC power is in use.
■ The DC receptacle is protected from an overload with a fuse. If the DC circuit is
overloaded, the 5 amp fuse will blow and power to the DC receptacle will cease. The red
light on the DC panel will illuminate. The fuse is located to the left of the receptacle and is
accessed by snapping open the access door. Replace the fuse with one of the same
capacity. Using a higher rated fuse may cause damage to the generator alternator.

5.8 Low oil alarm system

The low oil alarm system is designed to prevent engine damage caused by an insufficient
amount of oil in the crankcase. Before the oil level in the crankcase falls below a safe
limit, the low oil alarm system will automatically shut down the engine (the engine switch
will remain in the ON position).
If the low oil alarm system shuts down the engine the red low oil alarm indictor light will
come on when you operate the starter, and the engine will not run. If this occurs, search
for any oil leaks. Add engine oil to resume normal operation.
The DC output is to be used to charge batteries only.
Serious damage to the stator windings can occur if
connected to a DC motor or transformer.