8. TRANSPORTING/STORAGE

8.1 Transporting

When transporting the generator, turn the fuel valve lever OFF and keep the generator
level to prevent fluid spillage. Fuel vapors or spilled fuel may ignite. Transporting the
generator with gasoline in the fuel tank is prohibited.

8.2 Extended Storage:

1. Be sure the storage area is free of excessive humidity
and dust.
2. Drain the fuel.
a. Open the left side maintenance cover.
b. Turn fuel valve lever to ON and then loosen the
carburetor drain screw. Drain the gasoline from the
carburetor and fuel tank into a suitable container.
c. Tighten the carburetor screw, close the fuel valve lever and left side maintenance cover.
3. Once a month, recharge the battery.
4. Change the engine oil.
5. Remove the spark plug and pour a tablespoon of clean engine oil into the cylinder.
Crank the engine several revolutions to distribute the oil and then reinstall the spark plug.
6. Slowly pull the starter grip until resistance is felt. At this point, the piston is coming up
on its compression stroke and both the intake and exhaust valves are closed.
Storing the engine in this position will help protect it from internal corrosion.

8.3 Fuel Treatment and Generator Exercise:

Any small engine is very susceptible to fuel varnishing. Fuel systems have very small
orifices and passageways which can easily become clogged by fuel residue that takes the
form of gum and varnish. This can lead to hard starting and rough running and possibly
cause the engine not to start at all. As EPA regulations dictate no kits available to renew a
carburetor, carburetor replacement will be necessary. Fuel preservatives are readily
available at leading RV and marine dealers. Regularly add a fuel preservative to the
generator fuel tank or fuel supply. Drain the carburetor bowl prior to any storage period
longer than 30 days. Exercise the generator by running it at a 50% load for two hours
every month. This insures fresh fuel is run through the fuel system and prevents
varnishing. In addition, seals and engine components are lubricated and the chance of
carbon buildup in the upper cylinder head is lessened. Any moisture that has accumulated
in the generator windings is baked out as well as keeping the battery charged.