Battery Base Page

This page (FIG. 90) allows you to alter/set the power warning preferences, monitor battery status information, and alter
the display times for the battery warnings. The fields on this page are populated with information after the panel is
connected to an optional NXA-BASE/B Battery Base containing up to two NXT-BP batteries.
FIG. 90
Battery Base page
This page is ONLY available on Modero Table Top panels (NXT) using an NXA-BASE/B. The elements of the Battery
Base page are described in the table below:
Battery Base Page Elements
Back:
Connection Status icon:
Charge Status:
Panel Shutdown:
Low Battery Warning:
Very Low Battery Warning: The Very Low Battery Warning UP/DN buttons alter the time value
NXD/T-1200V Wall/Flush Mount Touch Panel
Saves the changes and returns you to the previously active touch panel page.
This visual display of the connection status allows the user to have a current visual update of
the panel's connection status regardless of what page is currently active.
• A Lock only appears on the icon if the panel has established a connection with a
currently secured target Master (requiring a username and password).
Time Remaining (blue) indicates the amount of charge time (use) remaining on the
batteries within the connected NXA-BASE/B.
Time Until Charged (green) indicates the amount of time remaining until the batteries
installed within the connected NXA-BASE/B are fully charged.
• Range = 0:00 - 12:59. This is read in HH:MM, hours and minutes.
The Panel Shutdown UP/DN buttons alter the timeout value (in minutes).
• This value determines the number of minutes that would need to pass before the panel
automatically shuts-down.
• Once shutdown, the unit would have to be restarted. A zero value disables this feature.
Range = 0 - 240, default = 0 min.
The Low Battery Warning UP/DN buttons alter the time value (in minutes) available on the
battery (for use) before the panel displays a low battery warning.
• Range - 10 - 45, default = 15 min.
(in minutes) available on the battery (for use) before the panel displays a very low battery
warning. This indicates a near-term panel shutdown.
Range = 3 - 15, default = 5 min.
- This value can never exceed the Low Battery Warning value.
• When the NXT-BP batteries (installed within the NXA-BASE/B battery base) reach
a point where they need to be recalibrated.
- A recalibration pop-up screen appears to ask whether or not you choose to recalibrate
the batteries at this time.
Firmware Pages and Descriptions