"^" Button Commands (Cont.)

^BOR

^BOS

^BPP

NXD/T-1200V Wall/Flush Mount Touch Panel
Set a border to a specific border style associated with a border value for those buttons with a defined
address range. Refer to theTPD4 Border Styles by Name table on page 112 for more information.
Syntax:
"'^BOR-<vt addr range>,<border style name or border value>'"
Variable:
variable text address range = 1 - 4000.
border style name = Refer to theTPD4 Border Styles by Name table on page 112.
border value = 0 - 41.
Examples:
SEND_COMMAND Panel,"'^BOR-500.504&510.515,10'"
Sets the border by number (#10) to those buttons with the variable text range of 500-504
& 510-515.
SEND_COMMAND Panel,"'^BOR-500.504&510,AMX Elite -M'"
Sets the border by name (AMX Elite) to those buttons with the variable text range of
500-504 & 510-515.
The border style is available through the TPDesign4 border-style drop-down list. Refer to theTPD4 Border
Styles by Name table on page 112 for more information.
Set the video window slot ID # to the new Slot ID #. The new Slot ID # is set only if the specified slot is not
the same as the current slot selected. Passthru sets the passthru mode to On. This is an optional
parameter and ONLY passes data to the PC.
Syntax:
"'^BOS-<vt addr range>,<button states range>,<slot number>,<passthru>'"
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
slot number = 0 = No Video Fill (Video Off)
1 = Composite Video (Video Fill) (Video On)
2 = Component RGB
3 = Streaming Video. 1200V panels only have Slot 1 available.
passthru = Passthru disable = 0 or Passthru enable = 2.
Example:
SEND_COMMAND Panel,"'^BOS-500,1,1'"
Sets the button to display Composite video with no pass-thru.
Refer to theVideo Adjustment Slide-Out Option Bar section on page 87 for more information on the slot
assignments within a panel.
Set or clear the protected page flip flag of a button. Zero clears the flag.
Syntax:
"'^BPP-<vt addr range>,<protected page flip flag value>'"
Variable:
variable text address range = 1 - 4000.
protected page flip flag value range = 0 - 4 (0 clears the flag).
Example:
SEND_COMMAND Panel,"'^BPP-500,1'"
Sets the button to protected page flip flag 1 (sets it to password 1).