Upgrading Modero Firmware
FIG. 74
Using USB for a Virtual Master transfer
8.
Select the panel's Kit file from the Files section.
9.
Enter the Device value associated with the panel and the System number associated with the Master (listed in the
OnLine Tree tab of the Workspace window). The Port field is greyed-out.
10.
Click the Reboot Device checkbox. This causes the touch panel to reboot after the firmware update process is
complete. The reboot of the panel can take up 30 seconds after the firmware process has finished.
11.
Click Send to begin the transfer. The file transfer progress is indicated on the bottom-right of the dialog (B in
FIG. 74).
12.
As the panel is rebooting, temporarily unplug the USB connector on the panel until the panel has completely
restarted.
13.
Reconnect the USB connector to the panel.
14.
Right-click the associated System number and select Refresh System. This causes a refresh of all project systems,
establishes a new connection to the Master, and populates the System list with devices on your particular system.
15.
Confirm the panel has been properly updated to the correct firmware version.

Upgrading the Modero Firmware via an IP Address

Before beginning with this section, verify that your panel is powered and connected to the NetLinx Master through an
Ethernet connection (direct or wireless).

Step 1: Prepare the Master for communication via an IP

1.
Obtain the IP Address of the NetLinx Master from your System Administrator. If you do not have an IP Address for
the Master, refer to your particular Master's instruction manual for more information on obtaining this IP Address
using NetLinx Studio 2.



2.
Launch NetLinx Studio 2.x (default location is Start > Programs > AMX Control Disc > NetLinx Studio 2 >
NetLinx Studio 2).
3.
Select Settings > Master Communication Settings from the Main menu to open the Master Communication
Settings dialog (FIG. 75).
72
A
From the Online Tree tab of the Workspace window, select the NetLinx Master.
Follow steps outlined in either the Obtaining or Assigning the Master's IP Address sections from your
particular NetLinx Master instruction manual to use an address.
Note the IP Address and Gateway information.
B
NXD/T-1200V Wall/Flush Mount Touch Panel