Configuring Communication
FIG. 51
Protected Setup page
7.
Press the on-screen Reboot button to restart the panel and incorporate any changes.
Before continuing, open NetLinx Studio 2.x. This program assists in developing a
System Number, Master IP/URL, and Master Port number. Refer to your NetLinx
Master's instruction manuals for more information.
8.
Obtain the System Number and Master IP Address from NetLinx Studio. This information must be specific for the
system used with the configured Modero panel.
9.
Press the grey Front Setup Access button for 3 seconds to open the Setup page.
10.
Press the Protected Setup button (located on the lower-left of the panel page) to open the Protected Setup page.
11.
Press the System Settings button (located on the Protected Setup page) to open the System Settings page (FIG. 52)
and begin configuring the communication settings on the panel to match those of the target Master.
Modero
connection
information
MAC Address
from panel is
factory set to a
unique address
FIG. 52
System Settings page
There are 2 possible Master Connection Types available: USB or Ethernet.
A USB connection type is a direct connection from the panel's mini-USB port to a
corresponding USB port on the PC (acting as a Virtual Master).
An Ethernet connection type involves indirect communication from the panel to a
Master via an Ethernet connection to the network.
It is recommended that firmware KIT files only be transferred over a direct connection
and only when the panel is connected to a power supply. If battery power or wireless
connection fails during a firmware upgrade, the panel flash file system may become
corrupted.
46
NetLinx Master's
connection
information