User-Changeable Sta Parameters - Enterasys VH-2402-L3 Management Manual

Vertical horizon fast ethernet switch
Hide thumbs Also See for VH-2402-L3:
Table of Contents

Advertisement

through the states of listening and learning at power up. If
properly configured, each port stabilizes to the forwarding or
blocking state.
No packets (except BPDUs) are forwarded from, or received
by, STP enabled ports until the forwarding state is enabled
for that port.
Default Spanning-Tree Configuration
Feature
Enable state
Port priority
Port cost
Bridge Priority

User-Changeable STA Parameters

The factory default setting should cover the majority of
installations. However, it is advisable to keep the default
settings as set at the factory; unless, it is absolutely
necessary. The user changeable parameters in the Switch
are as follows:
Priority A Priority for the switch can be set from 0 to
65535. 0 is equal to the highest Priority.
Hello Time The Hello Time can be from 1 to 10 seconds.
This is the interval between two transmissions of BPDU
packets sent by the Root Bridge to tell all other Switches
that it is indeed the Root Bridge. If you set a Hello Time
for your Switch, and it is not the Root Bridge, the set
Hello Time will be used if and when your Switch becomes
the Root Bridge.
9033691-01
Table 2-3. Default STP Parameters
Default Value
STP enabled for all ports
128
19
32,768
VH-2402-L3 Management Guide 123