Electrical system
- presenza delle alimentazioni alla centralina come
di seguito specificato:
With the key switch set to OFF:
- if there is battery voltage between terminals 6-26
and terminal 6-chassis ground (fixed power sup-
ply). If there is no voltage, check that fuse 6 and
its cable harness are in working order.
With the key switch in the OFF position:
- if there is battery voltage between terminals 5-26
and terminals 5-chassis ground (fixed power sup-
ply). If there is no voltage, check the key switch
contacts, and that fuses No. 1 and 9 and their ca-
ble harnesses are in working order.
- There is continuity between terminals 12-18 and
the emergency cut-off switch is set to «RUN» and
the side stand is folded up. If there is no continuity,
check the contacts of the latter.
After removing the shield back plate, remove the
electrical connection from the aerial as shown in
the photograph.
ELE SYS - 66
Beverly Tourer 250 i.e.