10

Operation

10.1

Manual

10.1.1

Capacity

10.1.2

Functions

"Pause" function
"Stop" function
"Priming" function
WARNING!
Danger of electric shock
Incompletely installed electrical options can allow moisture
into the inside of the housing.
Knock-out openings in the pump housing must be
equipped with matching modules or be sealed in a leak-
tight manner.
WARNING!
Danger of electric shock
A mains voltage may exist inside the pump housing.
If the pump housing has been damaged, you must dis‐
connect it from the mains immediately. It may only be
returned to service after an authorised repair.
Personnel:
n
The capacity is determined by the stroke length and the stroke rate.
The stroke length is adjusted by the stroke length adjustment knob within
a range of 0 ... 100 %. A stroke length of between 30 ... 100 % (SEK type:
50 ... 100 %) is recommended to achieve the specified reproducibility!
Data
Recommended stroke length, standard
type
Recommended stroke length, SEK type
The stroke rate can be set within a range of 10 ... 100 % using the multi‐
functional switch.
The pump has the following functions:
The pump can be remotely stopped via the "External Control" terminal.
The "Pause" function only works via the "External Control" terminal.
The pumps can be stopped by turning the multifunctional switch to "Stop"
without disconnecting it from the mains power supply.
Priming (transient conveyance at maximum frequency) can be provided by
turning the multifunctional switch to "Test".
Instructed personnel
30 ... 100 %
50 ... 100 %
Operation
Value Unit
33