Level Switch" Terminal; Relay; Fault Indicating Relay" Output (Identity Code 1 + 3 Or 4 + 5) - ProMinent Beta BT4b Operating Instructions Manual

Solenoid metering pump
Hide thumbs Also See for Beta BT4b:
Table of Contents

Advertisement

9.2.2 "Level Switch" terminal

1
P_BE_0016_SW
Fig. 10: Pump pin assignments
3
2
P_BE_0017_SW
Fig. 11: Cable conductor assignments

9.3 Relay

9.3.1 "Fault indicating relay" output (identity code 1 + 3 or 4 + 5)

2
P_SI_0010_SW
Fig. 12: Pump pin assignments
Indentity code 1 + 3
P_SI_0043
There is a connecting option for a 2-stage level switch with pre-warning
and limit stop.
Electrical interface
Data
3
Voltage with open contacts
Input resistance
Control via:
potential-free connection contact (load: 0.5 mA at 5 V) or
n
2
Semiconductor switch (residual voltage < 0.7 V)
n
Pin
1
2
3
1
A fault indicating relay can be ordered as an option - refer to ordering
information in the appendix. It is used to emit a signal when there is a fault
with the pump and for the "Liquid level low, 1st stage" warning alert and
"Liquid level low, 2nd stage".
A cut-off relay works when there are fault alerts from the pump and in the
event of the "Liquid level low 2nd stage" alert.
The fault indicating relay can be retrofitted and is operational once
attached to the relay board - refer to "Retrofitting Relays" in the Appendix.
Electrical interface
Data
Maximum contact load at 230 V and 50/60
Hz:
3
1
Minimum mechanical lifespan:
4
Pin assignment
Electrical installation
Function
3-conductor cable
Earth / GND
black
Minimum pre-warning
blue
Minimum limit stop
brown
Value Unit
5 V
10 kΩ
Value Unit
8 A
200 000 Switching
operations
31