Technical data
15.2.2

Self-Bleeding Liquid End

15.3

Viscosity

15.4

Material Data

Standard liquid ends
48
* - at max. stroke length and max. operating pressure for all material
versions
** - at constant conditions and min. 30 % stroke length
As the self-bleeding liquid end is used with outgassing media and when
operating with air bubbles, no dosing accuracy or reproducibility can be
provided.
The recommended minimum stroke length with self-bleeding dosing
pumps is 50 %.
The liquid ends are suitable for the following viscosity ranges:
Version
Range
standard
0 ... 200
With valve springs
200 ... 500
Self-bleeding (SEK)
0 ... 50
HV (highly viscous)
500 ... 3000*
* Only when the installation is correctly adjusted
Version
Dosing head Suction/Dis‐
PPE
Polypropy‐
lene
PPB
Polypropy‐
lene
PPT
Polypropy‐
lene
NPE
Acrylic glass
NPB
Acrylic glass
NPT
Acrylic glass
PVT
PVDF
TTT
PTFE with
carbon
SST
Stainless
steel 1.4404
Only the self-bleeding version in PPE, PPB, NPE and NPB material
models with a valve spring made of hastealloy C and a valve insert made
of PVDF. Diaphragm with a PTFE coating.
FPM = fluororubber
Unit
mPas
mPas
mPas
mPas
Seals
charge con‐
nector
Polypropy‐
EPDM
lene
Polypropy‐
FPM
lene
PVDF
PTFE
PVC
EPDM
PVC
FPM
PVDF
PTFE
PVDF
PTFE
PTFE with
PTFE
carbon
Stainless
PTFE
steel 1.4404
Valve balls
Ceramic
Ceramic
Ceramic
Ceramic
Ceramic
Ceramic
Ceramic
Ceramic
Ceramic

Hide quick links: