ProMinent Beta b BT4b Series Operating Instructions Manual

ProMinent Beta b BT4b Series Operating Instructions Manual

Solenoid metering pump
Hide thumbs Also See for Beta b BT4b Series:
Table of Contents

Advertisement

Operating instructions

Solenoid Metering Pump
Beta
b BT4b and BT5b
®
EN
Please carefully read these operating instructions before use. · Do not discard.
The operator shall be liable for any damage caused by installation or operating errors.
The latest version of the operating instructions are available on our homepage.
Part no. 986356
Original operating instructions (2006/42/EC)
BA BE 033 08/18 EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Beta b BT4b Series and is the answer not in the manual?

Questions and answers

Summary of Contents for ProMinent Beta b BT4b Series

  • Page 1: Operating Instructions

    Operating instructions Solenoid Metering Pump Beta b BT4b and BT5b ® Please carefully read these operating instructions before use. · Do not discard. The operator shall be liable for any damage caused by installation or operating errors. The latest version of the operating instructions are available on our homepage. Part no.
  • Page 2 Supplemental directives Supplementary information Read the following supplementary information in its entirety! You will ben‐ efit more from using the operating instructions should you already know this information. The following are highlighted separately in the document: Enumerated lists Fig. 1: Please read! Instructions ð...
  • Page 3: Table Of Contents

    Table of contents Table of contents Identity code..................5 About this pump................7 Safety Chapter................. 8 Storage, Transport and Unpacking..........13 Overview of Equipment and Control Elements......14 5.1 Overview of Equipment............14 5.2 Control Elements..............15 5.2.1 Pulse control switch............15 5.2.2 Stroke Length Adjustment Button........
  • Page 4 Table of contents Repairs..................42 13.1 Cleaning valves..............43 13.2 Replacing the diaphragm............ 45 Troubleshooting................48 14.1 Faults without a fault message..........48 14.2 Fault messages..............49 14.3 Warning messages............. 49 14.4 All other faults..............49 Decommissioning and disposal............. 50 15.1 Decommissioning..............
  • Page 5: Identity Code

    Identity code Identity code Product range Beta b BT4b Type Capacity 1000 0.74 1601 1.10 1602 2.20 1604 3.60 0708 7.10 0413 12.30 0220 19.00 BT5b 2504 2.90 1008 6.80 0713 11.00 0420 17.10 0232 32.00 Material of dosing head/valves Polypropylene/PVDF.
  • Page 6 Identity code Product range Beta b Connector for 10/4 hose, discharge side only Design Standard Logo with ProMinent logo Electrical connection 100 ... 230 V ± 10%, 50/60 Hz* Cable and plug 2 m European 2 m Swiss 2 m Australian...
  • Page 7: About This Pump

    About this pump About this pump Properties of the device This solenoid metering pump Beta b is equipped with all adjustment and activation functions for modern water treatment and the dosing of chemi‐ cals. It has pulse step-up and pulse step-down compared with the pre‐ ceding model.
  • Page 8: Safety Chapter

    Observe the general limitations with regard to viscosity limits, chem‐ ical resistance and density - see also ProMinent resistance list in the Product Catalogue or at www.prominent.com! All other uses or modifications are prohibited.
  • Page 9 Safety Chapter Safety information WARNING! Warning about personal and material damage The pump can start to pump, as soon as it is connected to the mains voltage. – Install an emergency cut-off switch in the pump power supply line or integrate the pump in the emer‐ gency cut-off management of the system.
  • Page 10 – Take into account the resistance of the wetted mate‐ rials and the ProMinent Resistance List when selecting the feed chemical - see the ProMinent Product Catalogue or visit ProMinent. CAUTION! Danger of injury to personnel and material damage The use of untested third party components can result in injury to personnel and material damage.
  • Page 11 Hood (houses the control elements) The dosing head may only be removed by the customer in accordance with the "Repair" chapter. The housing and the hood may only be removed by ProMinent customer service department. Information in the event of an emergency In an emergency, either pull out the mains plug, turn the multifunctional switch to "Stop"...
  • Page 12 Service The Service department refers to service technicians, who have received proven training and have been authorised by ProMinent to work on the system. Sound pressure level Sound pressure level LpA < 70 dB according to EN ISO 20361...
  • Page 13: Storage, Transport And Unpacking

    WARNING! The transporting of pumps which have been used with radioactive feed chemicals is forbidden! They will also not be accepted by ProMinent! WARNING! Only return metering pumps for repair in a cleaned state and with a flushed liquid end - refer to "Decommis‐...
  • Page 14: Overview Of Equipment And Control Elements

    Overview of Equipment and Control Elements Overview of Equipment and Control Elements 5.1 Overview of Equipment P_BE_0013_SW Fig. 2: Complete overview Control unit Drive unit Liquid end P_BE_0008_SW Fig. 3: Overview of liquid end (PV) Discharge valve Backplate Dosing head Bleed valve Bypass hose sleeve Suction valve...
  • Page 15: Control Elements

    Overview of Equipment and Control Elements 5.2 Control Elements Fig. 4 Pulse control switch Stroke Length Adjustment Button Fault indicator (red) Warning indicator (yellow) Operating indicator (green) Multifunctional Switch "External control" terminal Relay connection (optional) "Level switch" terminal 5.2.1 Pulse control switch In "External Contact"...
  • Page 16: Functional And Fault Indicators

    Overview of Equipment and Control Elements 5.2.4 Functional and Fault Indicators Fault indicator (red) The fault indicator lights up if the fluid level in the dosing tank falls below the second switching point of the level switch (20 mm residual filling level in the dosing tank).
  • Page 17: Functional Description

    Functional description Functional description 6.1 Liquid End The dosing process is performed as follows: The diaphragm is pressed into the dosing head; the pressure in the dosing head closes the suction valve and the feed chemical flows through the discharge valve out of the dosing head.
  • Page 18: Functions

    Functional description 6.6 Functions The functions are described below in the "Operation" chapter. 6.7 Relay The pump has two connecting options. Fault indicating relay option The relay can switch a connected power circuit (e.g. for an alarm horn) in the event of warnings or fault messages (e.g. warning levels). The relay can be retrofitted with the retrofit kit via a knock-out opening in the pump foot - refer to "Retrofitting relays".
  • Page 19: Assembly

    Assembly Assembly Compare the dimensions on the dimension sheet – with those of the pump. WARNING! Danger of electric shock If water or other electrically conducting liquids penetrate into the drive housing, in any other manner than via the pump's suction connection, an electric shock may occur. –...
  • Page 20: Installation, Hydraulic

    – Take into account the resistance of the wetted mate‐ rials and the ProMinent Resistance List when selecting the feed chemical - see the ProMinent Product Catalogue or visit ProMinent. CAUTION! FDA pumps only: problems with hygiene possible The O-rings supplied can become slightly contaminated through packaging and shipment.
  • Page 21: Installing Hose Lines

    Installation, hydraulic 8.1 Installing hose lines 8.1.1 Installation of metering pumps without bleed valve Safety information CAUTION! Warning of feed chemical spraying around The pipes can loosen or rupture if they are not installed correctly. – Route all hose lines so they are free from mechan‐ ical stresses and kinks.
  • Page 22 Installation, hydraulic CAUTION! Uncontrolled flow of feed chemical Feed chemicals can leak through the metering pump in an uncontrolled manner in the event of excessive pri‐ ming pressure. – Do not exceed the maximum permissible priming pressure for the metering pump. Align the pipes so that the metering pump and the liquid end can be removed from the side if necessary.
  • Page 23: Installation Of Metering Pumps With Bleed Valve

    Installation, hydraulic Hose Union nut Clamp ring Nozzle O-ring or flat seal Valve P_MAZ_0021_SW Fig. 5: PP, NP, PV and TT designs Installing stainless steel pipe - SS design Pull the union nut (2) and clamp rings (3, 4) over the pipe (1) with Ä...
  • Page 24: Installation Of Metering Pumps With Self-Bleeding (Sek Type)

    Installation, hydraulic Attach the hose line to the return hose nozzle or to the liquid end bleed valve. PVC hose, soft, 6x4 mm is recommended. Feed the free end of the return line into the storage tank. Shorten the return line so that it is not immersed in the feed chem‐ ical in the storage tank.
  • Page 25: Basic Installation Notes

    Installation, hydraulic P_MAZ_0023_SW_3 Fig. 7: SEK liquid end Anti-kink device Bleed valve for the return line into the storage tank, 6/4 mm Red sleeve Discharge valve for discharge line to the injection point, 6/4 - 12/9 mm Suction valve for suction line in the storage tank, 6/4 - 12/9 mm 8.1.4 Basic installation notes Safety notes CAUTION!
  • Page 26 Installation, hydraulic P_MAZ_0001_SW Fig. 8: Standard installation Main line Storage tank Legend for hydraulic diagram Symbol Explanation Symbol Explanation Metering pump Foot valve with filter meshes Injection valve Level switch Multifunctional valve Manometer...
  • Page 27: Electrical Installation

    Electrical installation Electrical installation WARNING! Danger of electric shock A mains voltage may exist inside the device. – Before any work, disconnect the device's mains cable from the mains. WARNING! Risk of electric shock This pump is supplied with a grounding conductor and a grounding-type attachment plug.
  • Page 28: Supply Voltage Connector

    Electrical installation CAUTION! Bonding of the contacts of your switching relay The high starting current can cause the contacts of the on-site switching relay to bond together if the mains voltage switches a solenoid metering pump on and off in a process.
  • Page 29: Supply Voltage Connector - Low Voltage

    The programmed thresholds apply to standard lead- – acid batteries. ProMinent can adapt them to cus‐ tomer requirements. Use short large-diameter power leads to minimise – faults. Use batteries with low internal resistance.
  • Page 30 Electrical installation Electrical interface for pin 1 "Pause" - pin 2 "External contact" - pin 5 "Aux‐ iliary frequency" Data Value Unit Voltage with open contacts Input resistance 10 kΩ Max. pulse frequency 25 pulse/s Min. pulse duration 20 ms P_BE_0014_SW Min.
  • Page 31: Level Switch" Terminal

    Electrical installation The pump works if: the cable is connected and pin 1 and pin 4 are connected. no cable is connected. "External contact" operating mode The pump performs one or more strokes if: Pin 2 and pin 4 are connected to each other for at least 20 ms. At the same time, pin 1 and pin 4 must also be connected to each other.
  • Page 32: Fault Indicating Relay" Output (Identity Code 1 + 3)

    Electrical installation Identity code Description Type Maximum voltage Maximum cur‐ Behaviour of relay rent type when retrofit‐ ting, as standard Fault indicating NO changeover 230 V relay contact Fault indicating 24 V 100 mA relay Pacing relay 24 V 100 mA Fault indicating 24 V 100 mA...
  • Page 33: Fault Indicating Relay" + "Pacing Relay" Output (Identity Code 4 + 5)

    Electrical installation 9.4.3 "Fault indicating relay" + "Pacing relay" output (identity code 4 + 5) A fault indicating / pacing relay can optionally be ordered. The pacing output is electrically-isolated by means of an optocoupler with a semicon‐ ductor switch. The second switch is a relay. The fault indicating /pacing relay can be retrofitted and is operational once attached to the relay board - refer to the "Operating Instructions for Retro‐...
  • Page 34: Start Up

    – Take into account the resistance of the materials that will come into contact with the medium when selecting the feed chemical - refer to the ProMinent ® Resistance List in the Product Catalogue or at www.prominent.com.
  • Page 35 Start up Reliable metering cannot be guaranteed after the – metering pump has been idle for some time, as the feed chemical can crystallise in the valves and on the diaphragm. Regularly check the valves and dia‐ phragm. Only adjust the stroke length when the pump is run‐ –...
  • Page 36 Start up With liquid ends with bleed valves (not SEK): Connect the suction and discharge line to the liquid end. Connect the return line. Open the bleed valve by turning the star-shaped handle in a counter-clockwise direction. ð You can now use the return line to bleed the pump. Switch on the metering pump and allow it to work at maximum stroke length and stroke rate until some feed chemical becomes visible in the return or discharge line.
  • Page 37: Operation

    Operation Operation WARNING! Fire hazard with flammable media Only with flammable media: They can be ignited by oxygen. – The pump may not work if there is a mixture of feed chemical with oxygen in the liquid end. A specialist may need to take appropriate actions (using inert gas, ...).
  • Page 38: External Contact

    Operation "Pause" function The pump can be remotely stopped via the "External Control" terminal. The "Pause" function only works via the "External Control" terminal. "Stop" function (optional) The pumps can be stopped by turning the multifunctional switch to "Stop" without disconnecting it from the mains power supply. "Priming"...
  • Page 39: External Analogue

    Operation 11.1.4 External analogue "External Analogue" operating mode In "External Analogue" operating mode, the stroke rate can be controlled by an mA signal via the pulse control switch. To do so, the multifunctional switch has to be turned to "Extern". In the same way, a single contact via the pulse control switch at the "external control"...
  • Page 40: Maintenance

    Maintenance Maintenance WARNING! It is mandatory that you read the safety information and specifications in the "Storage, Transport and Unpacking" chapter prior to shipping the pump. WARNING! Fire hazard with flammable media Only with flammable media: They can be ignited by oxygen.
  • Page 41 Maintenance P_BE_0012_SW Fig. 17: The leakage hole Liquid ends with bleed valve: Interval Maintenance work Quarterly* In addition: Check that the bypass line is fixed firmly to the liquid end Check that the bleed valve is tight. Check the discharge and bypass line for kinks Check that the bleed valve is operating correctly.
  • Page 42: Repairs

    WARNING! Danger of electric shock Unauthorised repairs inside the pump can result in an electric shock. For this reason, only allow a ProMinent branch or repre‐ sentative to perform repairs inside the pump, in partic‐ ular the following: – Replacement of damaged mains connection lines –...
  • Page 43: Cleaning Valves

    Repairs that may be carried out by qualified technical personnel, in accordance with the operating instructions: Cleaning valves Replacing the diaphragm All other repairs: Contact the responsible ProMinent branch! 13.1 Cleaning valves Warning of faulty operation Refer to the exploded drawings in the appendix when working on the unit.
  • Page 44 Repairs Please note, however, that: The flow direction of the suction connector is the opposite to that of the pressure connector.
  • Page 45: Replacing The Diaphragm

    Repairs 13.2 Replacing the diaphragm WARNING! A little feed chemical may have accumulated behind the diaphragm in the backplate following a leak - depending on the design! – Take this feed chemical into consideration when you are planning a repair - especially if it is hazardous! If necessary take protective measures.
  • Page 46 Repairs CAUTION! Leakage may become apparent at a later stage – Make sure that the leakage hole points down‐ wards when the pump is installed later - please refer to ! – Place the backplate (4) immediately into the correct position on the pump housing (6)! Do not twist the backplate on the pump housing to prevent the safety diaphragm (5) from becoming warped!
  • Page 47 Repairs P_BE_0018_SW Fig. 18: Partially exploded view of liquid end...
  • Page 48: Troubleshooting

    Troubleshooting Troubleshooting Safety information WARNING! Warning of hazardous feed chemical Should a dangerous feed chemical be used: it may escape from the hydraulic components when working on the pump, material failure or incorrect handling of the pump. – Take appropriate protective measures before working on the pump (e.g.
  • Page 49: Fault Messages

    Yellow LED display (warning The fluid level in the storage tank has Top up the storage Instructed per‐ indicator) lights up. reached "Liquid level low 1st stage". tank. sonnel 14.4 All other faults Please contact the responsible ProMinent branch or representative!
  • Page 50: Decommissioning And Disposal

    Decommissioning and disposal Decommissioning and disposal 15.1 Decommissioning WARNING! Danger from chemical residue There is normally chemical residue in the liquid end and on the housing after operation. This chemical residue could be hazardous to people. – It is mandatory that the safety information in the "Storage, transport and unpacking"...
  • Page 51: Disposal

    Decommissioning and disposal Disconnect the pump from the mains/power supply. Drain the liquid end by turning the pump upside down and allowing the feed chemical to run out. Flush the liquid end with a suitable medium; flush the dosing head thoroughly when using hazardous feed chemicals! 15.2 Disposal...
  • Page 52: Technical Data

    Technical data Technical data 16.1 Performance data Beta b operating at 180 strokes/minute and 100 % stroke length Type Pump capacity Pump capacity Connec‐ Suction Priming Max‐ tion size lift* lift** imum at maximum back pressure at medium back pressure priming outer Æ...
  • Page 53 Technical data Type Pump capacity Pump capacity Connec‐ Suction Priming Max‐ tion size lift* lift** imum at maximum back pressure at medium back pressure priming outer Æ pressure x inner on suc‐ Æ tion side m WS m WS stroke stroke 0401 0.083...
  • Page 54: Accuracy

    Technical data - Suction lift with a filled suction line and filled liquid end. With self- bleeding dosing head with air in the suction line. ** - Priming lift with clean and moist valves. Priming lift at 100% stroke length and free outlet or opened bleed valve. *** - The given performance data constitutes guaranteed minimum values, calculated using water as the medium at room temperature.
  • Page 55: Material Specifications

    Technical data 16.4 Material specifications Standard liquid ends Design Dosing head Suction/ Seals Valve balls pressure connector Polypropy‐ Polypropy‐ EPDM Ceramic lene lene Polypropy‐ Polypropy‐ Ceramic lene lene Polypropy‐ PVDF PTFE Ceramic lene Clear acrylic EPDM Ceramic Clear acrylic Ceramic Clear acrylic PVDF PTFE...
  • Page 56 Technical data Data Value Unit Current I eff 0.9 ... 0.3 A Peak current 5.9 ... 2.3 A Switch on peak current, (within approx. 15 A 50 ms falling) Fuse* 0.8 AT * Fuses must have VDE, UL and CSA certification. E.G. type 19195 manu‐ factured by Wickmann in compliance with IEC Publ.
  • Page 57: Temperatures

    Technical data # SELV in accordance with EN 60335-1 * 5 AT, 5x20 mm, order no. 712028 The pump only works if the polarity is correct. 16.6 Temperatures Pump, fully assembled Data Value Unit Storage and transport temperature: -10 ... +50 °C Ambient temperature in operation (power -10 ...
  • Page 58: Degree Of Protection And Safety Requirements

    Technical data Exposure in a humid and alternating climate: FW 24 according to DIN 50016 16.8 Degree of Protection and Safety Requirements Degree of protection Protection against contact and humidity: IP 66 according to DIN EN 60529 with contamination level 2 NEMA 4X / indoor as per NEMA 250 Safety Requirements Degree of protection:...
  • Page 59: Dimensional Drawings

    Dimensional drawings Dimensional drawings Compare the dimensions on the dimensional – drawing with those of the pump. All dimensions are in mm. – Dimensional drawing Beta b, material ver‐ sion PP 10.85 41 / 36 10 / 15 92 / 102 81 / 100 131.5 / 148.6 P_BE_0019_SW...
  • Page 60 Dimensional drawings Dimensional drawing Beta b, material ver‐ sion NP 12.9 P_BE_0020_SWx_2 Fig. 20: Dimensional drawing Beta b BT4b/BT5b, material version NP - dimensions in mm 1000 - 1604 0708 - 0220 2504 1008 - 0420 0232 24.6 182.8 178.4 198.8 131.5 131.5...
  • Page 61 Dimensional drawings Dimensional drawing Beta b, material ver‐ sion PP and NP SEK P_BE_0021_SW_3 Fig. 21: Dimensional drawing @Beta b BT4b/BT5b, material versions PP and NP with self-bleeding dosing head SEK - dimensions in mm 1601 - 0401 0708 - 0413 1008/0713 1602 - 0404 0220...
  • Page 62 Dimensional drawings Dimensional drawing Beta b, material ver‐ sion PV 29.3 P_BE_0022_SWx_2 Fig. 22: Dimension drawing Beta b BT4b/BT5b, material version PV - dimensions in mm 1000 - 0402 0708 - 0220 1008 - 0420 0232 1604 - 0404 14.1 185.5 191.5 131.5...
  • Page 63 Dimensional drawings Dimensional drawing Beta b, material ver‐ sion PV HV 41 / 36 10 / 15 92 / 102 81 / 100 131.5 / 148.5 P_BE_0023_SWx_2 Fig. 23: Dimensional drawing Beta b BT4b/BT5b, material version PV for high-viscosity feed chemicals - dimensions in 1604 0708 - 0413 0220...
  • Page 64 Dimensional drawings Dimensional drawing Beta b, material ver‐ sion SS 92 / 102 41 / 36 10 / 15 81 / 100 131.5 / 148.6 P_BE_0025_SWx_2 Fig. 25: Dimensional drawing Beta b BT4b/BT5b, material version SS - dimensions in mm 1000 - 1601 1602 - 1604 0708 - 0220...
  • Page 65: Diagrams For Setting The Capacity

    Diagrams for setting the capacity Diagrams for setting the capacity C [l/h] BT4b 0400 f [%] BT4b 1000 C [l/h] f [%] 180 min 90 min 180 min 90 min 72 min 162 min 162 min 72 min 144 min 54 min 144 min 54 min...
  • Page 66 Diagrams for setting the capacity C [l/h] BT4b 1001 f [%] C [l/h] BT4b 0401 f [%] 180 min 90 min 180 min 90 min 72 min 162 min 72 min 162 min 144 min 54 min 144 min 54 min 126 min 36 min 126 min...
  • Page 67 Diagrams for setting the capacity C [l/h] BT4b 0402 f [%] C [l/h] BT4b 1002 f [%] 180 min 90 min 180 min 90 min 72 min 162 min 72 min 162 min 54 min 144 min 144 min 54 min 126 min 36 min 126 min...
  • Page 68 Diagrams for setting the capacity BT4b 0708 BT4b 0704 C [l/h] f [%] C [l/h] f [%] 180 min 90 min 180 min 90 min 72 min 162 min 72 min 162 min 54 min 144 min 54 min 144 min 126 min 36 min 126 min...
  • Page 69 Diagrams for setting the capacity BT5b 2504 BT4b 0413 C [l/h] f [%] C [l/h] f [%] 180 min 90 min 180 min 90 min 72 min 162 min 72 min 162 min 54 min 144 min 54 min 144 min 126 min 36 min 126 min...
  • Page 70 Diagrams for setting the capacity BT5b 1008 C [l/h] BT5b 0420 f [%] C [l/h] f [%] 180 min 90 min 180 min 90 min 72 min 162 min 72 min 162 min 144 min 54 min 144 min 54 min 126 min 36 min 126 min...
  • Page 71: Exploded Drawings And Ordering Information

    Exploded drawings and ordering information Exploded drawings and ordering information 19.1 Exploded drawings Liquid end Beta b 1000 - 1604 PP_2 P_BE_0038_SW Fig. 32...
  • Page 72 Exploded drawings and ordering information Tab. 11: Spare parts for liquid end Beta b 1000 - 1604 PP_2 Pos. Description Connector kit Discharge valve Diaphragm Suction valve Liquid end Beta b 1000 PP_2 PPE2 PPB2 PPT2 Liquid end 1002057 1002065 1035317 Spare parts kit 1001644...
  • Page 73 Exploded drawings and ordering information Liquid end Beta b 0708 (1008) - 0220 (0420) PP_2 P_BE_0039_SW Fig. 33...
  • Page 74 Exploded drawings and ordering information Tab. 12: Spare parts for liquid end Beta b 0708 (1008) - 0220 (0420) PP_2 Pos. Description Connector kit Discharge valve Diaphragm Suction valve Liquid end Beta b 0708 (1008) PP_2 PPE2 PPB2 PPT2 Liquid end 1002061 1002069 1035321...
  • Page 75 Exploded drawings and ordering information Liquid end Beta b 0232 PP_0 P_BE_0034_SW Fig. 34...
  • Page 76 Exploded drawings and ordering information Tab. 13: Spare parts kit for liquid end Beta b 0232 PP_0 Pos. Description Connector kit Discharge valve Diaphragm Suction valve Liquid end Beta b 0232 PPE0 PPB0 PPT0 Liquid end 1002064 1002072 1035324 Spare parts kit 1001651 1001659 1023124...
  • Page 77 Exploded drawings and ordering information Liquid end Beta b 1000 - 1604 NP_0 and NP_2 P_BE_0035_SW Fig. 35...
  • Page 78 Exploded drawings and ordering information Tab. 14: Spare parts for liquid end Beta b 1000 - 1604 NP NP_0 and NP_2 Pos. Description Connector kit Discharge valve Diaphragm Suction valve Liquid end Beta b 1000 NPE_ NPB_ NPT_ Liquid end with 1002193 1002201 1034560...
  • Page 79 Exploded drawings and ordering information Liquid end Beta b 0708 (1008) - 0220 (0420) NP_0 and NP_2 P_BE_0036_SW Fig. 36...
  • Page 80 Exploded drawings and ordering information Tab. 15: Spare parts for liquid end Beta b 0708 (1008) - 0220 (0420) NP_0 and NP_2 Pos. Description Connector kit Discharge valve Diaphragm Suction valve Liquid end Beta b 0708 (1008) NPE_ NPB_ NPT_ Liquid end with 1002197 1002205...
  • Page 81 Exploded drawings and ordering information Liquid end Beta b 0232 NP_0 and NP_2 P_BE_0037_SW Fig. 37...
  • Page 82 Exploded drawings and ordering information Tab. 16: Spare parts for liquid end Beta b 0232 NPT0 and NPT2 Pos. Description Connector kit Discharge valve Diaphragm Suction valve Liquid end Beta b 0232 NPE_ NPB_ NPT_ Liquid end with 1002200 1002208 1034567 bleed valve, _2 Liquid end...
  • Page 83 Exploded drawings and ordering information Liquid end Beta b 1000 - 1604 PV_2 P_BE_0032_SW Fig. 38...
  • Page 84 Exploded drawings and ordering information Tab. 17: Spare parts for liquid end Beta b 1000 - 1604 PV_2 Pos. Description Connector kit Discharge valve Diaphragm Suction valve Liquid end Beta b 1000 PVT2 Liquid end 1023134 Spare parts kit 1023107 Diaphragm 1000244 Liquid end Beta b 1601...
  • Page 85 Exploded drawings and ordering information Liquid end Beta b 0708 (1008) - 0220 (0420) PV_2 P_BE_0033_SW Fig. 39...
  • Page 86 Exploded drawings and ordering information Tab. 18: Spare parts for liquid end Beta b 0708 (1008) - 0220 (0420) PV_2 Pos. Description Connector kit Discharge valve Diaphragm Suction valve Liquid end Beta b 0708 (1008) PVT2 Liquid end 1023138 Spare parts kit 1023111 Diaphragm 1000248...
  • Page 87 Exploded drawings and ordering information Liquid end Beta b 0232 PV_0 P_BE_0034_SW Fig. 40...
  • Page 88 Exploded drawings and ordering information Tab. 19: Spare parts kit for liquid end Beta b 0232 PV_0 Pos. Description Connector kit Discharge valve Diaphragm Suction valve Liquid end Beta b 0232 PV_0 Liquid end 1023141 Spare parts kit 1023124 Diaphragm 1000251...
  • Page 89 Exploded drawings and ordering information Liquid end Beta b 1604 - 0220 (0420) PV_4 P_BE_0047_SW P_BE_0047_SW Fig. 41...
  • Page 90 Exploded drawings and ordering information Tab. 20: Spare parts kit for liquid end Beta b 1604 - 0220 (0420) PV_4 Pos. Description Connector kit with hose nozzle Diaphragm Liquid end Beta b 1604 PV_4 Liquid end 1035326 Spare parts kit 1035342 Diaphragm 1034612...
  • Page 91 Exploded drawings and ordering information Liquid end Beta b 1000 - 1604 TTT0 P_BE_0029_SW Fig. 42...
  • Page 92 Exploded drawings and ordering information Tab. 21: Spare parts for liquid end Beta b 1000 - 1604 TTT0 Pos. Description Connector kit Discharge valve Diaphragm Suction valve Liquid end Beta b 1000 TTT0 Liquid end 1002345 Spare parts kit 1001737 Diaphragm 1000244 Liquid end Beta b 1601...
  • Page 93 Exploded drawings and ordering information Liquid end Beta b 0708 (1008) - 0220 (0420) TTT0 P_BE_0030_SW Fig. 43...
  • Page 94 Exploded drawings and ordering information Tab. 22: Liquid end Beta b 0708 (1008) - 0220 (0420) TTT0 Pos. Description Connector kit Discharge valve Diaphragm Suction valve Liquid end Beta b 0708 (1008) TTT0 Liquid end 1002349 Spare parts kit 1001741 Diaphragm 1000248 Liquid end Beta b 0413 (0713)
  • Page 95 Exploded drawings and ordering information Liquid end Beta b 0232 TTT0 P_BE_0031_SW Fig. 44...
  • Page 96 Exploded drawings and ordering information Tab. 23: Spare parts kit for liquid end Beta b 0232 TTT0 Pos. Description Connector kit Discharge valve Diaphragm Suction valve Liquid end Beta b 0232 TTT0 Liquid end 1002352 Spare parts kit 1001755 Diaphragm 1000251...
  • Page 97 Exploded drawings and ordering information Liquid end Beta b 1000 - 1604 SS_0 P_BE_0026_SW Fig. 45...
  • Page 98 Exploded drawings and ordering information Tab. 24: Spare parts for liquid end Beta b 1000 - 1604 SS_0 Pos. Description Connector kit Discharge valve Diaphragm Suction valve Liquid end Beta b 1000 SST0 Liquid end 1002337 Spare parts kit 1001729 Diaphragm 1000244 Liquid end Beta b 1601...
  • Page 99 Exploded drawings and ordering information Liquid end Beta b 0708 (1008) - 0220 (0420) SS_0 P_BE_0027_SW Fig. 46...
  • Page 100 Exploded drawings and ordering information Tab. 25: Spare parts for liquid end Beta b 0708 (1008) - 0220 (0420) SS_0 Pos. Description Connector kit Discharge valve Diaphragm Suction valve Liquid end Beta b 0708 (1008) SST0 Liquid end 1002341 Spare parts kit 1001733 Diaphragm 1000248...
  • Page 101 Exploded drawings and ordering information Liquid end Beta b 0232 SS_0 P_BE_0028_SW Fig. 47...
  • Page 102 Exploded drawings and ordering information Tab. 26: Spare parts kit for liquid end Beta b 0232 SS_0 Pos. Description Connector kit Discharge valve Diaphragm Suction valve Liquid end Beta b 0232 SST0 Liquid end 1002344 Spare parts kit 1001736 Diaphragm 1000251...
  • Page 103 Exploded drawings and ordering information Liquid end Beta b 1602 - 1604 SER, self- bleeding without bypass, NPT7 P_BE_0035_SW Fig. 48...
  • Page 104 Exploded drawings and ordering information Tab. 27: Spare parts for liquid end Beta b 1602 - 1604 SER, self-bleeding without bypass, NPT7 Pos. Description Connector kit Discharge valve Diaphragm Suction valve Liquid end Beta b 1602 NPT7 Liquid end SER, self-bleeding 1075598 without bypass Spare parts kit...
  • Page 105 Exploded drawings and ordering information Liquid end Beta b 0708 (1009) - 0220 (0420) SER, self-bleeding without bypass, NPT7 P_BE_0036_SW Fig. 49...
  • Page 106 Exploded drawings and ordering information Tab. 28: Spare parts for liquid end Beta b 0708 (1009) - 0220 (0420) SER, self-bleeding without bypass, NPT7 Pos. Description Connector kit Discharge valve Diaphragm Suction valve Liquid end Beta b 0708 (1008) NPT7 Liquid end SER, self-bleeding 1075600 without bypass...
  • Page 107 Exploded drawings and ordering information Liquid end Beta b 1602 - 1604 SER, self- bleeding without bypass, PVT7 P_BE_0032_SW Fig. 50...
  • Page 108 Exploded drawings and ordering information Tab. 29: Spare parts for liquid end Beta b 1602 - 1604 SER, self-bleeding without bypass, PVT7 Pos. Description Connector kit Discharge valve Diaphragm Suction valve Liquid end Beta b 1602 PVT7 Liquid end SER, self-bleeding 1048634 without bypass Spare parts kit...
  • Page 109 Exploded drawings and ordering information Liquid end Beta b 0708 (1008) - 0220 (0420) SER, self-bleeding without bypass, PVT7 P_BE_0033_SW Fig. 51...
  • Page 110 Exploded drawings and ordering information Tab. 30: Spare parts for liquid end Beta b 0708 (1008) - 0220 (0420) SER, self-bleeding without bypass, PVT7 Pos. Description Connector kit Discharge valve Diaphragm Suction valve Liquid end Beta b 0708 (1008) PVT7 Liquid end SER, self-bleeding 1048637 without bypass...
  • Page 111 Exploded drawings and ordering information Liquid end Beta b 1601 - 1604 PP_9 and NP_9 P_BE_0041_SW Fig. 52...
  • Page 112 Exploded drawings and ordering information Pos. Part 1, 9, 10 Connector kit Bleed valve Discharge valve Diaphragm Suction valve Tab. 31: Liquid ends Type Order no. PPE9 1601 1002393 1602 1002395 1604 1035301 PPB9 1601 1002392 1602 1002394 1604 1035302 Tab.
  • Page 113 Exploded drawings and ordering information Spare parts kits for Material version Order no. type: 1602 1001667 1604 1035334 Diaphragm for type: Order no. 1601 1000245 1602 1000246 1604 1034612...
  • Page 114 Exploded drawings and ordering information Liquid end Beta b 0708 (1008) - 0220 (0420) PP_9 and NP_9 P_BE_0040_SW Fig. 53...
  • Page 115 Exploded drawings and ordering information Pos. Part 1, 9, 10 Connector kit Bleed valve Discharge valve Diaphragm Suction valve Tab. 33: Liquid ends Type Order no. PPE9 0708 / 1008 1002397 0413 / 0713 1002401 0220 / 0420 1002403 PPB9 0708 / 1008 1002396 0413 / 0713...
  • Page 116: Ordering Information

    Fault indicating relay for Beta ® Fault indicating/pacing relay for 1029310 Beta ® Further sources of information Further information on spare parts, accessories and options can be found the exploded drawings the identity code under www.prominent.com the ProMinent product catalogue...
  • Page 117: Declaration Of Conformity For Machinery, Mains Voltage

    In accordance with DIRECTIVE 2006/42/EC OF THE EUROPEAN PAR‐ LIAMENT AND OF THE COUNCIL, Appendix I, BASIC HEALTH AND SAFETY REQUIREMENTS, section 1.7.4.2. C. ProMinent GmbH Im Schuhmachergewann 5 - 11 D - 69123 Heidelberg, Germany, hereby declare that the product specified in the following complies with the relevant basic health and safety rules of the EC Directive, on the basis of its functional concept and design and in the version marketed by us.
  • Page 118: Declaration Of Conformity For Machinery, Low Voltage

    In accordance with DIRECTIVE 2006/42/EC OF THE EUROPEAN PAR‐ LIAMENT AND OF THE COUNCIL, Appendix I, BASIC HEALTH AND SAFETY REQUIREMENTS, section 1.7.4.2. C. ProMinent GmbH Im Schuhmachergewann 5 - 11 D - 69123 Heidelberg, Germany, hereby declare that the product specified in the following complies with the relevant basic health and safety rules of the EC Directive, on the basis of its functional concept and design and in the version marketed by us.
  • Page 119: Approvals

    Approvals Approvals - see Chapter “Declaration of Conformity” It consists of EAC certification with certificate no. TC N RU D- DE.AY14.B.02691...
  • Page 120: Index

    Index Index 1, 2, 3 ... External frequency changeover ....18 External frequency changer ....16 "External control"...
  • Page 121 Index Operating modes ..... 15, 16, 17 Standard installation ......26 Operating Modes .
  • Page 124 ProMinent GmbH Im Schuhmachergewann 5-11 D-69123 Heidelberg, Germany Telephone: +49 6221 842-0 Fax: +49 6221 842-419 Email: info@prominent.com Internet: www.prominent.com 986356, 8, en_GB © 2009...

Table of Contents