Operation
"Level switch" function
"Auxiliary rate" function
10.1.3
External contact
"Extern" operating mode:
10.2
Remote operation
34
Information about the liquid/powder level in the feed chemical container is
reported to the pump. To do so, a two-stage level switch must be fitted; it
is connected to the "Level switch" terminal.
Enables switching of a stroke rate via the "External control" jack. This aux‐
iliary frequency has priority over the operating mode stroke rate settings .
In the standard version, the "Auxiliary frequency" function is programmed
to 100 % stroke rate.
In the Extern Contact operating mode, either a series of strokes can be
triggered or an inbound series of contacts can be stepped down via the
pulse control switch by a single contact on the "External control" terminal.
To do so, the multifunctional switch has to be turned to "Extern".
Explanation of the stepped-down values:
Settable values
Incoming contacts
1:1
1
1:2
2
1:4
4
1:8
8
1:16
16
1:32
32
1:64
64
Explanation of stepped-up values:
Settable values
Incoming contacts
1:1
1
2:1
1
4:1
1
8:1
1
16:1
1
32:1
1
64:1
1
There is an option to control the pump remotely via a signal cable - refer to
your system documentation and to "Electrical Installation".
Strokes performed
1
1
1
1
1
1
1
Strokes performed
1
2
4
8
16
32
64