Type
Minimum pump capacity
at maximum back pressure
bar
l/h
0401
4
0.9
2002
20
0.78
1602
16
1.40
1002
10
1.7
0702
7
1.8
0402
4
2.1
1604
16
2.7
1004
10
3.3
0704
7
3.6
0404
4
3.9
0708
7
6.60
0408
4
7.5
0413
4
10.8
0220
2
16.2
1008
10
6.3
0713
7
10.5
0420
4
15.6
15.2
Accuracy
15.2.1
Standard Liquid End
Minimum pump capacity
at medium back pressure
ml/
bar
l/h
stroke
0.083
2.0
1.2
0.07
10.0
1.8
0.13
8.0
1.74
0.16
5.0
2.0
0.17
3.5
2.2
0.19
2.0
2.5
0.25
8.0
3.6
0.30
5.0
3.9
0.33
3.5
4.0
0.36
2.0
4.2
0.61
3.5
7.50
0.64
2.0
8.1
1.0
2.0
12.6
1.5
1.0
18.0
0.58
5.0
7.5
0.97
3.5
12.3
1.44
2.0
17.4
*
- Suction lift with a filled suction line and filled liquid end. With self-
bleeding dosing head with air in the suction line.
** - Priming lift with clean and moist valves. Priming lift at 100 % stroke
length and free outlet or opened bleed valve.
*** - The given performance data constitutes guaranteed minimum
values, calculated using medium water at room temperature. The
bypass connection with a self-bleeding dosing head is 6x4 mm.
- The connector width is 6 mm on SST material versions.
1
Beta b Metering pumps with dosing heads for higher-viscosity media have
a 10-20 % lower metering capacity and are not self-priming. Connection
G 3/4-DN 10 with tube nozzle d16-DN10.
Data
Capacity range of the series
Reproducibility
Con‐
Suction
nector
lift*
size
outside
Æ x
inside Æ
ml/
mm
m WS
stroke
0.11
6x4
6.0
0.17
6x4
6.0
0.174
6x4
6.0
0.18
6x4
6.0
0.20
6x4
6.0
0.23
6x4
6.0
0.33
6x4
5.0
0.36
6x4
5.0
0.37
6x4
5.0
0.39
6x4
5.0
0.69
8x5
4.0
0.77
8x5
4.0
1.17
8x5
3.0
1.67
12x9
2.0
0.69
8x5
3.0
1.14
8x5
2.5
1.61
12x9
2.5
Technical data
Priming
Max‐
lift**
imum
priming
pressure
on suc‐
tion side
m WS
bar
2.0
0.5
2.5
0.5
2.5
0.5
2.5
0.5
2.5
0.5
2.5
0.5
3.0
0.5
3.0
0.5
3.0
0.5
3.0
0.5
2.0
0.5
2.0
0.5
2.5
0.5
2.0
0.5
3.0
0.5
2.5
0.5
2.5
0.5
Value Unit
-5 ... +10 % *
±2 % **
47