12

Lubricating jig changeover

.05
Fig. 12 - 08
Press the home position key on the control panel of the folder station. (Transport arm
with sewing jig swings to home position).
Press key 1 for the sewing jig changeover.
(Changeover of transport arm and sewing jig frame is released.)
Remove sewing jig frame and grease the changeover bushes 2.
Also lightly grease the catch 3 of the X/Y control.
Position the sewing jig frame on the transport arm and activate key 1. (Changeover is
now closed again.)
2
1
Grease the parts described below regularly with Retinax G (sodium-base
grease; dripping point 135°C), Part. no. 280-1-120 243.
Care and maintenance
3
Fig. 12 - 09
12 - 6