13
Height of pocket plate support
.08.09
Requirement
The plungers 3 must be flush with the raised table 4.
Fig. 13 - 48
Turn screws 1 (grub screws 2) according to the requirement.
Depending on the size of the pocket plate, the plungers which are not in the
pocket plate area can be lowered.
To do this, press the plunger up lightly, turn by 90° and lower.
3
Adjustment
2
1
3
4
13 - 50