Emptying the water trap

.07.04
Place a suitable container under the drain opening.
12

Adjusting the drip feed rate on the oil vaporizer

.07.05
Adjust regulating screw 5 so that adequate lubrication of the cylinders and valves is
guaranteed (1 drop per 30 work cycles).
12

Cleaning the vaporizer jet

.07.06
Unscrew regulating screw 5 as far as possible.
Unscrew vaporizer jet 6 and blast with compressed air in the direction of the arrow.
Observe the seal when putting back together.
Open compressed air and readjust drip feed rate.
Make sure that the knurled bush 4 is unscrewed as far as it will go (left-hand
thread).
When the water level rises, the automatic drain opens and the water is drained
off.
This adjustment is not required when the machine is not operated with
lubricated air.
Turn off the compressed air.