Counter Presser Position - Pfaff 3568-12/22 Instruction Manual

Table of Contents

Advertisement

13

Counter presser position

.06.21
Requirement
1. When the needle penetrates, it must be centered in the needle hole in the counter
presser 5.
2. When the needle bar is at BDC, the counter presser 5 must be at its front point of
reversal and with the back edge of the needle hole resting against the needle.
Fig. 13 - 23
Turn crank 1 (screw 2) so that the counter presser 3 travels 0.6 - 1 mm, and the needle,
when it penetrates, is centered in the needle hole in the counter presser 3.
Loosen screws 4 just enough so that the eccentric 5 is difficult to turn on the shaft.
Bring needle bar to BDC.
Turn eccentric 5 until the counter presser 3 is in its back point of reversal and tighten
screws 4.
Move counter presser 3 carrier (screws 6) until the the back edge of the needle hole of
the counter presser 3 is resting against the needle (see arrow).
6
3
Move counter presser 3 carrier (screws 6) until the the back edge of the needle
hole of the counter presser 3 is resting against the needle (see arrow).
Adjustment
4
5
4
1
2
13 - 24