NV11 Manual Set – Section 3
To use a USB connection with the NV11, a USB cable fitted with a 16 way connector
on one end (ITL Part Number CN392) should be used. The CN392 cable fits into the
16 way connector and allows high speed programming and serial communications
when used in SSP and ccTalk modes. When using the USB connection, power must be
supplied to the NV11 using the red and black power leads on the CN392 cable.
The NV11 validator must be powered up for the interface to be recognised by
Windows. If the validator is not in the host machine, you will need to provide power
to the 16 way interface connector first. The connection information and pin numbering
is as follows:
Before connecting the USB cable to the computer, make sure that the CN392 cable is
connected to the validator and that the unit is powered up. Once you have carried out
these steps, plug the USB cable into the computer.
After connecting the USB cable, Windows
should then detect the NV11 validator
interface – a 'Found New Hardware'
bubble or dialog box should appear.
A 'Found New Hardware' wizard should then start to guide you through the installation
process (this first screen is not always shown on some computers):
Copyright © Innovative Technology Ltd 2012
Pin
Description
1
Serial Data Out (Tx)
5
Serial Data In (Rx)
11
USB Data +
12
USB Data -
13
USB Power (+5V)
15
+ V
16
0V / Ground Connection